background image

14

Type BM5A

OS/80X Series Slam-Shut Controller 

(See Figure 8)

Key Description

 1 

Plate

  2 

Releasing bushing

 3 

Screw

 4* 

Gasket

  5 

Balls holder

 6 

Stem

 7 

Roller

 8* 

O-ring

  9 

Reloading nut

  10 

Ball (Roller for Type OS/80X-R)

 11 

Roller

 12 

Dowels

  13 

Reloading bushing

 14*  O-ring
 15 

Ring

  17 

Reloading lever unit

  18 

Self-locking nut

 19 

Washer

  20 

Return lever

 21 

Spring

 22 

Fulcrum

 24 

Label

 26 

Nut

 27 

Screw

  28 

Reloading pin

 29 

Screw

  30 

Self-locking nut

 31 

Washer

  32 

Plate fulcrum

 33 

Lever

 34 

Screw

 35 

Cone

  36 

Releasing lever

 37 

Spring

 38 

Plug

  39 

Locking pin

Key Description

 40 

Screw

  41 

Indicator pin

  42 

On-Off indicator

 43 

Button

 44*  O-ring
 45 

Spring

 46 

Gasket

 47 

Casing

 48 

Screw

  49 

Minimum pressure (UPSO) adjusting screw

  50 

Maximum pressure (OPSO) adjusting nut

  51 

Pipe assembly

 52 

Washer

 53 

Spring

 54 

Spring

  55 

Lower spring holder unit

  56 

Seeger ring

  57 

Stem unit

 58 

Spring

  59 

Plate holding stem unit

  60 

Top cover (Body for Types OS/84X and OS/88X)

  61 

Lower cover (Plug for Types OS/84X and OS/88X)

 62*  Diaphragm
 63 

Screw

 64 

Block

 65*  O-ring

  66* 

Gaco flex

 67*  O-ring
 68 

Piston

 69 

Locknut

 70 

Nut

 71 

Microswitch

  73* 

Gasket (only for Types OS/80X-BP, -BPA-D and -MPA-D)

 74 

Filter

* Rubber parts are supplied in the “spare parts kit”, recommended as stock.

Summary of Contents for TARTARINI BM5A

Page 1: ...agement Regulator Technologies Inc Emerson instructions If the slam shut valve vents gas or a leak develops in the system service to the unit may be required Failure to correct trouble could result in a hazardous condition Call a gas service person to service the unit Only a qualified person must install or service the slam shut valve Introduction Scope of the Manual This Instruction Manual provid...

Page 2: ... 725 psig CL600 RF 0 to 100 bar 0 to 1450 psig Overpressure Set Range Wdo CL300 RF 0 03 to 50 0 bar 0 44 to 725 psig CL600 RF 0 03 to 80 0 bar 0 44 to 1160 psig Underpressure Set Range Wdu CL300 RF 0 01 to 50 0 bar 0 15 to 725 psig CL600 RF 0 01 to 80 0 bar 0 15 to 1160 psig Accuracy Class AG Up to 1 Response Time ta 1 s Minimum Maximum Allowable Temperature TS 1 2 Class 1 10 to 60 C 14 to 140 F W...

Page 3: ...ufacturer recommendations are not put into practice before installation and if purge by inert gas is not carried out before equipment s start up and shut down operations a potential external and internal explosive atmosphere can be present in equipment and gas pressure regulating measuring stations or installations If a presence of foreign material in the pipelines is foreseen and purge by inert g...

Page 4: ...e and a controller which keeps the valve open in normal conditions The slam shut valve features a shutter valve sliding axially therefore no by pass is needed for its opening even in the presence of pressurized gas This valve can only be opened manually by turning the eccentric shaft counterclockwise Figure 3 Type OS 80X BP Slam Shut Controller Table 2 OS 80X and OS 80X PN Series Slam Shut Control...

Page 5: ... OS 80X PN Series slam shut controller The controllers are supplied in different models according to set ranges required The Type BM5A with DN 150 NPS 6 body size is equipped with a reinforced version Type OS 80X R OS 80X or OS 80X PN Series slam shut controller is used to keep the slam shut valve shutter open These Series are designed to operate on Overpressure Shutoff OPSO only Underpressure Shu...

Page 6: ...ES B SUPPLY PORT L LOADING PORT A SENSING PORT TYPES PSA 79 PSA 80 PSA 79 AP AND PSA 80 AP V SENSING PORT M SUPPLY PORT R LOADING PORT S BLEED PORT L L Figure 5 Type BM5A Typical Connection Installation Schematics OUTLET PRESSURE BM5A SERIES SLAM SHUT VALVE TYPE PS 79 1 TYPE PS 79 1 MONITOR BM5A SERIES SLAM SHUT VALVE BLEED JET 1 mm 0 04 IN TYPE PS 79 OR PSA 79 TYPE PS 79 OR PSA 79 REGULATOR MONIT...

Page 7: ...3 7 2 Ensure that the data found on the slam shut valve and slam shut controller label are compatible with usage requirements Ensure the slam shut is not damaged and remove all foreign materials that might have collected during shipping Clean out all pipelines before installing the slam shut valve Install the slam shut valve in any position desired unless otherwise specified but be sure flow throu...

Page 8: ...protection if the slam shut valve outlet pressure can be greater than the maximum allowable pressure PS of the pilot differential strength type Slam shut valve operation below the limits specified in the specifications section and slam shut valve label does not preclude the possibility of damage from external sources or debris in the line Startup WARNING Remove lever unit key 137 from reset stem k...

Page 9: ...ng shall also be covered after every subsequent reassembly at installation site in order to ensure that the equipment will be safe throughout its intended life The slam shut device should be tested for both under and overpressure shutoff activation and seat leak annually with test intervals not to exceed 15 months and at least one each calendar year If the slam shut device does not close at the de...

Page 10: ... A to release pressure inside the slam shut controller After maintenance operation check the tightness of the connections with suds Routine slam shut controller maintenance entails periodic checking of the diaphragm on the Type OS 80X the piston Gaco flex on the Type OS 84X and the movement of the levers the levers should move freely with minimum friction If necessary lubricate pins with silicone ...

Page 11: ... slam shut valve is working properly Cut off Test 1 Cut off the fluid flow to slam shut valve by closing upstream and downstream isolation valves and disconnect the pressure sensing line to port A of slam shut controller The slam shut controller should cut off for minimum pressure Underpressure Shut off UPSO if set 2 Through port A using a small pump or other appropriate means raise the pressure t...

Page 12: ...LOW DOWNWARD FLOW Figure 6 Type BM5A Slam Shut Valve Flow Orientation Table 3 Approximate Weights END CONNECTION STYLE DN 25 NPS 1 DN 50 NPS 2 DN 80 NPS 3 DN 100 NPS 4 DN 150 NPS 6 kg lbs kg lbs kg lbs kg lbs kg lbs CL300 RF CL600 RF 17 37 5 30 66 62 137 105 231 280 617 ...

Page 13: ...as necessary Sleeve has dirt deposits Check sleeve and clean as necessary Shaft unit key 121 is damaged Check shaft unit and repair or replace as necessary Parts List Type BM5A Slam Shut Valve See Figure 7 Key Description 100 Inlet flange 101 Pad holder 102 Pad unit 103 Pad retainer 104 Screw 105 Label 106 Rivet 107 O ring 108 Label support 109 Label 110 Disk 111 Washer 112 Nut 113 Stud bolt 114 S...

Page 14: ...37 Spring 38 Plug 39 Locking pin Key Description 40 Screw 41 Indicator pin 42 On Off indicator 43 Button 44 O ring 45 Spring 46 Gasket 47 Casing 48 Screw 49 Minimum pressure UPSO adjusting screw 50 Maximum pressure OPSO adjusting nut 51 Pipe assembly 52 Washer 53 Spring 54 Spring 55 Lower spring holder unit 56 Seeger ring 57 Stem unit 58 Spring 59 Plate holding stem unit 60 Top cover Body for Type...

Page 15: ...0 111 112 113 100 118 114 115 117 R E M E M R A I R E G N R G C E Y M E T E S ON E R OFF OS 80X O ENZA 104 103 102 101 121 122 123 124 125 126 127 128 120 119 108 15 Type BM5A Figure 7 Type BM5A Slam Shut Valve Assembly MLM1499 ...

Page 16: ... 103 104 129 119 120 121 122 124 125 133 134 128 130 131 132 131 126 PAD HOLDER DN 65 NPS 2 1 2 TO DN 150 NPS 6 DN 150 NPS 6 REOPENING HUB DN 150 NPS 6 LEVER UNIT 16 Type BM5A Figure 7 Type BM5A Slam Shut Valve Assembly continued MLM1499 ...

Page 17: ...4 7 15 8 1 9 10 71 12 11 22 20 21 19 18 17 13 14 40 5 10 6 17 Type BM5A Figure 8 OS 80X Series Slam Shut Controller Assembly Standard Version MLM1389 DETAIL OF OS 80X SERIES WITH PROXIMITY SWITCH DETAIL OF TYPE OS 80X R REINFORCED FOR TYPE BM5A DN 150 NPS 6 SECTION D D SECTION C C ...

Page 18: ...22 B 30 46 B C A 45 44 60 29 41 42 19 18 43 47 48 49 50 51 52 53 54 52 55 56 58 57 59 61 62 C 26 48 69 70 33 73 D D 39 18 Type BM5A Figure 8 OS 80X Series Slam Shut Controller Assembly Standard Version continued MLM1389 SECTION B B SECTION A A ...

Page 19: ... 66 60 27 65 62 61 67 61 68 34 59 63 64 60 66 67 61 74 74 74 73 68 73 27 19 Type BM5A Figure 8 OS 80X Slam Shut Controller Assembly Standard Version continued MLM1389 TYPE OS 80X APA D DETAIL TYPE OS 80X MPA D DETAIL TYPE OS 80X BPA D DETAIL TYPE OS 84X DETAIL TYPE OS 88X DETAIL ...

Page 20: ...agement Regulator Technologies Inc All rights reserved 01 21 The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Tartarini is a mark owned by O M T Officina Meccanica Tartarini s r l a business of Emerson Automation Solutions The contents of this publication are presented for informational purposes only and while ever...

Reviews: