General

Your Emerson Ceiling Fan/Light Wall
Control consists of a wall mount transmitter
and a receiver. The SW102 transmitter
works in conjunction with the receiver. The
receiver is mounted under the fan ceiling
cover. The wall control is designed to
separately control your ceiling fan speed
and light intensity.

Code switches in the wall control and
receiver may be set in 16 different
positions. If your fan and light go on and off
without using your control, you may be
getting interference from other transmitters
such as garage door openers, car alarms
or security systems. To remedy this
situation, simply change the combination
code in your wall control and receiver.
(See Figure 2.)

ON

1

2

3

4

WALL CONTROL
LEVERS

RECEIVER

HI

HI

MED

MED

LOW

LOW

FAN  OFF

LIGHT

ON

1

2

3

4

RECEIVER SWITCH
LEVERS

CODE
SWITCH

SW102 WALL 
CONTROL

Figure 2

Figure 1

Your SW102 Fan/Light Wall Control and
Receiver have code switches which must
be set in one of 16 possible code
combinations. The four levers (numbered
1, 2, 3, and 4) on the switches are factory-
set in the ON (up) position. Change the
switch settings as follows:

1. Slide the four switch levers in the wall

control to your choice of ON (up) or
down positions. Use a ball-point pen or
small screwdriver and slide the levers
firmly up or down (Figure 2).

2. In the receiver, slide the four switch

levers to the same positions as set in the
wall control. Make sure the levers on
both switches are in the same positions,
otherwise the fan will not operate.

The SW102 Fan/Light Wall Control
transmits the command signals via
radio waves to the receiver installed in
the ceiling fan ceiling cover. The
receiver is required for the SW102 wall
control to function. Power for the
SW102 wall control comes from the 12V
battery, located in the wall control.

Replacement 12V battery recommended
are Duracell MN21 and Eveready A23.

1. Install the 12V battery (supplied) into

the wall control (Figure 3). 

2. The SW102 wall control is supplied with

a white, ivory or almond color cover.
Choose the style that best suits your
needs and snap the cover onto the wall
control (Figure 3).

12V BATTERY

WALL
CONTROL
COVER

SW102 WALL
CONTROL

HI

HI

MED

MED

LOW

LOW

FAN  OFF

LIGHT

Battery Installation

of Wall Control

Turning off wall switch is not
sufficient. To avoid possible
electrical shock, be sure electricity
is turned off at the main fuse or
circuit breaker box.

WARNING

!

Figure 3

Setting Operating

Frequency of Wall

Control and Receiver

Installation of Receiver

(Figure 1)

1. After electricity has been turned off at

main fuse box or circuit breaker box,
remove the ceiling cover from the hanger
bracket.

2. Disconnect the supply wiring to the fan

by removing wire connectors. Do not
disconnect the green/bare ground wires.

3. Connect the black supply wire to the

receiver black wire (AC IN L). Connect
the white supply wire to the receiver
white wire (AC IN N). Use only listed wire
connectors (supplied) to make
connections.

To avoid possible electrical shock,
be sure electricity is turned off at the
main fuse or circuit breaker box
before installing the receiver.

WARNING

!

4. Connect the receiver white wire (TO

MOTOR N) to the fan white wire.
Connect the receiver red wire (TO
MOTOR L) to the fan black wire. Connect
the receiver blue wire (FOR LIGHT) to
the fan blue wire.

CAUTION: If no light exist on your
ceiling fan, cap the blue wire on the
receiver with a wire connector.

5. Push the connected wires up into the

junction 

box and position the receiver in the

hanger bracket above the hanger ball. Lay the
antenna wire on top of the receiver.

6. Reinstall the ceiling cover and restore

electrical power to the circuit.

BARE

GREEN/GROUND

ANTENNA

WHITE

TO

AC SUPPLY

WHITE

BLACK

BLUE

WHITE

RED

BLUE

RECEIVER

FAN HOUSING

LIGHT

1 2 3 4

BLACK

WHITE

RED

BLUE

HANGER
BALL

CEILING
COVER

ANTENNA

HANGER
BRACKET

RECEIVER

Summary of Contents for SW102

Page 1: ... No BP7345 Form No F40BP73450000 Printed in China 09 07 READ AND SAVE THESE INSTRUCTIONS Model SW102 For use only with Emerson Ceiling Fans Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Replacement 12V battery recommended are Duracell MN21 and Eveready A23 ...

Page 2: ...LL COSTS OF REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE WALL CONTROL TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center To return the product to the factory obtain a return authorization and service...

Page 3: ...ttery recommended are Duracell MN21 and Eveready A23 1 Install the 12V battery supplied into the wall control Figure 3 2 The SW102 wall control is supplied with a white ivory or almond color cover Choose the style that best suits your needs and snap the cover onto the wall control Figure 3 12V BATTERY WALL CONTROL COVER SW102 WALL CONTROL HI HI MED MED LOW LOW FAN OFF LIGHT Battery Installation of...

Page 4: ...erate your fan on high medium or low speed See Figure 5 2 To turn your fan off press the FAN OFF button 3 To set the level of light brightness press and hold the LIGHT button The light brightness will continue to increase then decrease while the button is held down When the light is at the desired brightness release the button LIGHT BUTTON FAN SPEED BUTTONS FAN OFF BUTTON RED INDICATOR LIGHT FAN O...

Reviews: