background image

LIMITED WARRANTY

What The Warranty Covers:
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your Remote Control
or Receiver ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,
MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:
Emerson will replace a defective Emerson Remote Control or Receiver at no charge to you. We will ship the
repaired product or replacement to you at no charge, but you are responsible for all costs or removal,
reinstallation and shipping of the product to Emerson.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE REMOTE CONTROL OR RECEIVER TO OBTAIN
LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the
product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to

Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136.
Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest

authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized
service center. Your Emerson Remote Control or Receiver should be properly packed to avoid damage in transit
since we will not be responsible for any such damage.

What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your remote control while in your

possession, or

• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal

wear and tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are
voided when:
• The original purchaser or user ceases to own the product, or
• The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other
written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any
warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS
WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL
AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of
time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing
other property which was damaged if this product does not work properly.

How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above
exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

Part No. F40BP72700000

Printed in China 05/05

Form No. BP7270

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant ¥ St. Louis, MO 63136

BP7270-1  5/6/05  1:29 PM  Page 12

Summary of Contents for SR110

Page 1: ...wner s Manual For use only with Emerson Ceiling Fan Models F2100 1 F2200 1 F2300 1 CF1 0 CF2300 0 CF2400 1 CF2500 0 CF2800 0 CF3900 0 CF4500 1 and CF4800 1 OFF REV LOW MED HIGH UP DN Model SR110 Remote Control Model SW105 Receiver NOTE The SR110 Remote Control must be used with a SW105 Receiver BP7270 1 5 6 05 1 29 PM Page 1 ...

Page 2: ... to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications...

Page 3: ...rol transmitter and how to set the operating frequency of the transmitter and receiver These instructions must be performed prior to installation of the ceiling fan as described in the second section CEILING FAN PROCEDURES REMOTE CONTROL PROCEDURES General Your Emerson Ceiling Fan Light Remote Control consists of a hand held transmitter and a receiver which is mounted under the fan ceiling cover T...

Page 4: ...ing Figure 2 2 All Ceiling Fan Models Disconnect the motor connector from the wiring harness connector Figure 2 Remove the knurled nut securing the speed control switch to the switch housing HOUSING COVER TYPICAL SCREW TYPICAL SCREW 2 KNURLED NUT SPEED CONTROL SWITCH PULL CHAIN PLUG REVERSING SWITCH SWITCH HOUSING CAPACITOR MOTOR CONNECTOR WIRING HARNESS CONNECTOR Figure 2 3 For Ceiling Fan Models...

Page 5: ...he uplight switch or reversing switch by installing pull chain plug s supplied in the hole s See Figures 2 3 and 4 Choose the color that best matches our ceiling fan 9 Position the reversing module supplied in the switch cup connect the reversing module connector to the motor connector Figure 6 The connectors are color coded and keyed and can be connected in only one manner Figure 6 10 Using a wir...

Page 6: ...he wire Strip 1 2 inch of insulation from the end of this wire Then join the 80 yellow wire to the yellow wire from the uplight using a wire connector supplied Figure 9 NOTE The red and brown wires coming from the top of the motor are capped with wire connectors DO NOT remove these connectors 14A For Ceiling Fan Models CF2400 Only Cut the yellow wire midway between the motor coupling and the gromm...

Page 7: ...rod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 22 17 Separate untwist and unkink the 80 white black and blue motor lead wires Route the three motor leads and the 80 yellow lead wire used only on fans with uplight through the downrod Seat the downrod firmly in the motor coupling Figure 11 18 Align the clevis pin holes in the downrod with the holes in the m...

Page 8: ... securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING SETSCREW DOWNROD PIN HANGER BALL CEILING COVER Figure 13 24 Install the hanger bracket and hang the fan in accordance with the instructions in the Ceiling Fan Owner s Manual 25 Pull the wire leads coming from the end of the downrod and the supply wires through the open sid...

Page 9: ...OFF REV D L U L YELLOW FAN WIRE FROM UPLIGHT Figure 15 27 Using wire connectors supplied make wiring connections as follows Figure 14 and 15 a Connect the green ground wires from the hanger bracket and the hanger ball to the supply ground wire bare or green b Connect the white fan wire and the white supply wire to the white receiver wire AC IN MOTOR N c Connect the black fan wire to the black rece...

Page 10: ...ECEIVER CEILING COVER HANGER BRACKET 1 1 4 THREADED STUDS 2 Figure 16 Operation IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control Figure 17 has full control of your fan and lights NOTE Prior to operation of the downlight from the remote control make sure the switch on the light is ON 1 To set the desir...

Page 11: ...from excessive heat or humidity Trouble Shooting FAN LIGHT FAILS TO OPERATE Check that the light switch on the light fixture is on Check that the battery is good red indicator light should light when any button is pressed Check that the receiver is wired properly Check that the ON OFF wall switch is in the ON position Check that the receiver and transmitter code switches are set in the same positi...

Page 12: ...e will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your remote control while in your possession or Unreasonable use misu...

Reviews: