Markings
Intrinsically Safe Class I, Division 1, Groups A, B, C, and D
T3C(T
a
≤ +70 °C) Warning – refer to QIG 825-0100-4701 for
Safe I.S. Use
(See
for parameters)
Special Condition for Safe Use (X):
The power modules are certified as components for use in intrinsically safe
products where the suitability/combination of use in the final assembly shall
be subjected to CSA acceptance. The final assembly must incorporate all
protection features necessary for batteries in accordance with applicable
standards of the final intrinsically safe application.
5.6
Europe
5.6.1
KF ATEX Intrinsic Safety
Certificate:
Baseefa11ATEX0042X
Standards:
EN 60079-0: 2018, EN 60079-11: 2012
Markings
II 1 G Ex ia IIC T4 Ga, T4(-55 °C ≤ T
a
≤ +70 °C)
II 1 G Ex ia IIC T5 Ga, T5(-55 °C ≤ T
a
≤ +40 °C)
or
Special Condition for Safe Use (X):
The plastic enclosure of the Model 701P SmartPower Power Modules may
constitute a potential electrostatic ignition risk and caution should be used
when being handled.
Note
This condition of use does not apply after a Power Module is installed within
a wireless transmitter enclosure.
5.7
International
5.7.1
KF IECEx Intrinsic Safety
Certificate:
IECEx BAS 11.0026X
Standards:
IEC 60079-0: 2011, IEC 60079-11: 2011
Markings:
Ex ia IIC T4/T5 Ga, T4(-55 °C ≤ T
a
≤ +70 °C), T5(-55 °C ≤ T
a
≤
+40 °C)
August 2022
Quick Start Guide
Quick Start Guide
13