2.0 Important Safety Instructions
2.1 Safety Precautions—SAVE THESE INSTRUCTIONS
This manual contains important safety instructions that should be followed during the installation of the Uninterruptible
Power Supply (UPS). Please read all safety, installation, and operating instructions before attempting to install or operate the
UPS. Follow all warnings on the unit and in this manual during installation and operation.
•
To prevent the risk of fire or electric shock, install the UPS in a temperature and humidity controlled ventilated enclosure, free of
conductive contaminants, moisture, flammable liquids, gases, and corrosive substances.
•
To reduce the risk of electric shock, do not remove the cover, as it has no user-serviceable parts inside. Some components are
live, even when ac power is disconnected. For service, contact a qualified technician.
Although your UPS has been designed and manufactured to assure personal safety, improper use can result in electrical
shock or fire. To ensure safety, please observe the following rules:
•
Turn OFF UPS and disconnect the ac supply before cleaning. Do not use liquid or aerosol cleaners. A dry cloth is recommended
to remove dust from the surface of your UPS.
•
Do not install or operate the UPS in or near water.
•
Do not place the UPS on an unstable cart, stand, or table.
•
Do not place the UPS under direct sunlight or close to heat-emitting sources.
•
To allow proper ventilation of the UPS, do not block or cover the top and bottom sides of the unit. Do not insert any objects into
the ventilation holes or other openings of the UPS. Keep all vents free of dust accumulation that could restrict airflow.
•
Do not dispose of batteries in a fire; they may explode. Do not open or damage the battery. Released electrolyte is harmful to the
skin and eyes and may be toxic.
•
This equipment is suitable for use in Class
I,
Div 2, Groups A, B, C, D, T3. When installed in a hazardous location, adhere to the
following:
•
Cet équipement est adapté pour une utilisation dans la Classe
I
, la Division 2, les groupes A, B, C, D, T3. Lorsqu’il est installé dans
un endroit dangereux, respecter les points suivants:
•
WARNING - EXPLOSION HAZARD
- Do not disconnect equipment unless power has been removed or the area is known to
be non-hazardous.
•
AVERTISSEMENT - RISQUE D’EXPLOSION
-
Ne pas débrancher l’équipement sauf si l’alimentation a été retirée ou si la
zone est reconnue comme non dangereuse.
•
WARNING - EXPLOSION HAZARD
- Batteries must only be replaced in an area known to be non-hazardous.
•
AVERTISSEMENT - RISQUE D’EXPLOSION
-
Les piles ne doivent être remplacées que dans une zone connue comme non
dangereuse.
•
WARNING - EXPLOSION HAZARD
- Do not reset circuit breaker unless power has been removed from the equipment or
the area is free of ignitible concentrations.
•
AVERTISSEMENT - RISQUE D’EXPLOSION
-
Ne pas réinitialiser le disjoncteur sauf si l’alimentation a été retirée de
l’équipement ou si la zone est exempte de concentrations inflammables.
If your UPS demonstrates any of the following conditions, turn OFF the UPS, disconnect the ac supply and contact your local
distributor, SolaHD representative or SolaHD Technical Support at 1-800-377-4384.
•
The circuit breaker opens frequently.
•
The UPS does not operate in accordance with the user manual.
2