Remote Mount Socket Module
Figure 12-4:
12.7
Installed sensor tests
If a problem with an installed sensor is identified, refer to
through
assist in troubleshooting the sensor. Disconnect or turn off power to the transmitter
before performing any of the sensor tests. Always check the operation of test equipment
before each test.
If possible, take all readings from feed-through pins in the sensor adapter. If the pins in the
sensor adapter are inaccessible, take measurements at the sensor terminal block or
through remote cabling as close to the sensor as possible. Readings taken through remote
cabling that is more than 100 feet (30 meters) in length may provide incorrect or
inconclusive information and should be avoided.
The expected values in the test below assume the measurements have been taken directly
at the pins.
Test A. Sensor coil
Table 12-8:
Test conditions
Expected
value
Potential cause
Corrective action
•
Location: installed or unin-
stalled
•
Required equipment: multi-
meter
•
Measuring at connections: 1
and 2 = R
2Ω
≤R≤
18Ω
•
Open or shorted coil
•
Remove and replace sensor
Troubleshooting
Reference manual
173
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...