Reference Manual
00809-0100-4728, Rev HA
December 2002
3-3
Models 644H and 644R
HART Menu Tree
Options listed in bold type indicate that a selection provides other options. For
ease of operation, changing calibration and setup, such as sensor type,
number of wires, and range values, can be completed in several locations.
Figure 3-1. HART Communicator Menu Tree
The review menu lists all of the
information stored in the Model 644. This
includes device information, measuring
element, output configuration, and
software revision
1. TEST DEVICE
2.
CALIBRATION
3. Write Protect
On-line Menu
1. Snsr 1 Digital Reading
2. Terminal Digital Reading
1. Snsr 1 Input Trim
2. Snsr 1 Trim-Fact
3. Active Calibrator
1. Loop Test
2. Self test
3. Master Reset
4. Status
1. SNSR 1 TRIM
2. D/A trim
3. Scaled D/A trim
1. Revision #s
2. Sensor Review
3. Dev Outputs Review
4. Device Information
5. Measurement
Filtering
1. PROCESS
VARIABLES
2. DIAGNOSTICS
AND SERVICE
3. CONFIGURATION
4. REVIEW
1. VARIABLE
MAPPING
2. SENSOR
CONFIGURATION
3. DEVICE OUTPUT
CONFIGURATION
4. DEVICE
INFORMATION
5. MEASUREMENT
FILTERING
1. TRANSMITTER VARS
2. PV is
3. PV Digital Reading
4. PV AO
5. PV% rnge
6. PV LRV
7. PV URV
8. PV Lower Sensor Limits
9. PV Upper Sensor Limits
10.PV Damping
1. DEVICE SETUP
2. PV is
3. PV
4. PV AO
5. % RNGE
6. PV LRV
7. PV URV
1. PV is
2. SV is
3. TV is
4. QV is
5. Variable re-map
1. SENSOR 1
2. TERMINAL TEMP
1. Connections
2. SNSR 1 SETUP
3.
CAL VANDUSEN
4. Sensor S/N
1. Terminal Units
2. Terminal Damp
3. Terminal LSL
4. Terminal USL
1. PV RANGE
VALUES
2. ALARM
SATURATION
3. HART OUTPUT
4. LCD METER
OPTIONS
1. AO Alarm Type
2. Low Alarm
3. High Alarm
4. Low Sat.
5. High Sat.
1. Poll Addr
2. Num Req Preams
3. Burst Mode
4. Burst Option
1. Meter Configuration
2. Meter Decimal Pt
1. Tag
2. Date
3. Descriptor
4. Message
5. Final Assembly number
1. 50/60 Hz Filter
2. Active Calibrator
3. Open Sensor Holdoff
4. Intermit Detect
5. Intermit Thresh
1. 2-wire Offset
2. Snsr 1 Units
3. Snsr 1 Damp
4. Snsr LSL
5. Snsr USL
1. R0
2. Alpha
3. Delta
4. Beta
1. PV LRV
2. PV URV
3. PV Damping
4. PV Units
5. Apply Values
6. PV LSL
7. PV USL
8. PV Min. Span
These numbers are to
be entered by the user.
When the hardware alarm
switches are changed, the
Model 275 should be power
cycled to see new readings.
Summary of Contents for Rosemount 644h
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 2 16 ...
Page 50: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 4 10 ...
Page 64: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R A 14 ...
Page 77: ......