7
Reference Manual
00809-0100-4570, Rev DA
Mechanical Installation
November 2017
Mechanical Installation
Section 3
Mechanical Installation
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Mounting considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Moisture and water condensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Physical mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17
3.1
Installation procedure
Make sure all required documentations are available: Application Evaluation Form (AEF) and Vessel
Drawings.
Compare locator suggestion or mounting location as suggested by Emerson
™
with the actual
Rosemount
™
5708 mounting positions.
Perform manual measurements of the vessel dimensions, and compare results to the drawings.
Check 24 Vdc input to all Rosemount 5708.
Check RS-485 link between Rosemount 5708 and the other side. Make sure the resistance between D+
and D- is 60 ±5%
Ω.
Check 4-20 mA connection to the local PLC. Perform Current Simulation from the Rosemount 5708
connected to the PLC.
Power up the Rosemount 5708 and check polling address.
Set polling address. In daisy chain connection make sure that each Rosemount 5708 has a different
polling address and one of the Rosemount 5708 is set with polling address of 00.
In case of daisy chain connection, write the polling addresses on the vessel drawings for all Rosemount
5708.
Verify every Rosemount 5708 for proper functioning after power up. This can be verified by connecting
each device directly to a computer.
Verify sound signals transmission from all Rosemount 5708.
Get material status (level/distance/volume) according to the process manager.
Get all required information from the process manager in order to complete the Rosemount 5708
configuration.
3.2
Mounting considerations
This chapter describes the necessary steps for proper installation of the Rosemount 5708 beginning
with important pre-installation considerations such as environmental conditions, correct positioning
and orientation, through the mounting and configuration process.
Summary of Contents for Rosemount 5708
Page 1: ...Reference Manual 00809 0100 4570 Rev DA November 2017 Rosemount 5708 3D Solids Scanner ...
Page 2: ...ii Section Title November 2017 Reference Manual 00809 0100 4570 Rev DA ...
Page 8: ...vi Reference Manual 00809 0100 4570 Rev DA Contents November 2017 Contents ...
Page 12: ...2 Reference Manual 00809 0100 4570 Rev DA Introduction November 2017 Introduction ...
Page 202: ...ii Reference Manual 00809 0100 4570 Rev DA Index November 2017 Index ...
Page 203: ...iii Reference Manual 00809 0100 4570 Rev DA November 2017 ...