126
Reference Manual
00809-0100-4570, Rev DA
Operation
November 2017
Operation
Figure 7-95. Measurement Summary Table
Demo mode
The Demo mode is useful for demonstration and marketing purposes, and for understanding system
operation.
The Demo mode loads a demo project with pre-defined sites, vessels, and devices and their
configuration, and activates a simulation of filling/emptying operations over time. Most software
features are available in demo mode, allowing the user to view reports, 3D visualizations, logs, and
time-based charts and their behavior over time.
To initiate the Demo mode:
1. On the
Tools
menu, select
Demo
>
Start Demo Running
. The
Projects
window appears with a list of
various demo projects, such as Aggregates, Chemicals, Food, and more.
2. Select a demo project and click
Select
. The demo project loads with all its sites, vessels, and devices,
and simulation begins.
The following options are available in the
Tools
>
Demo
drop-down menu:
Stop Demo Running
: Exits the demo mode and opens a project selection box.
Restart Demo Running
: Brings the demo values to their initial levels and continues the simulation
while keeping demo history.
Fast Run/Normal Run/Slow Run
: Runs the demo mode simulation at various speeds. By default, the
Normal Run option is selected.
Reset Demo Date (Server)
: Restarts the demo mode.
Note
The demo mode must be stopped before the system can return to normal operation. Exiting and
restarting the application will not stop the demo mode.
7.5.12
User management
The Rosemount 3DVision/3DMultiVision software enables several user levels. Each level has different
authorizations for accessing system features. Multiple users can be added to the system and their
authorization levels set.
The available user level options are:
Administrator – Has all privileges except for changing device configuration, communication and
polling address. Default user name: admin, default password: admin
Senior Technician – Has privileges to configure all of the devices parameters including configuration
wizard, advanced parameters and more. Default user name: stech, default password: techS
Viewer – Only has viewing capabilities.
Summary of Contents for Rosemount 5708
Page 1: ...Reference Manual 00809 0100 4570 Rev DA November 2017 Rosemount 5708 3D Solids Scanner ...
Page 2: ...ii Section Title November 2017 Reference Manual 00809 0100 4570 Rev DA ...
Page 8: ...vi Reference Manual 00809 0100 4570 Rev DA Contents November 2017 Contents ...
Page 12: ...2 Reference Manual 00809 0100 4570 Rev DA Introduction November 2017 Introduction ...
Page 202: ...ii Reference Manual 00809 0100 4570 Rev DA Index November 2017 Index ...
Page 203: ...iii Reference Manual 00809 0100 4570 Rev DA November 2017 ...