Reference Manual
00809-0100-4882, Rev AB
May 2019
Rosemount 5081FG
3-12
Trim 4mA
Refer to Figure 3-14. Use this screen to trim the 4 mA value of the 4-20 mA
output.
NOTE
Before trimming the 4 mA value you must break the loop to add the ammeter.
Power down the unit, connect the ammeter in series with Rosemount 5081
transmitter terminals 15(-) and 16(+), power up the unit, and return to the
TRIM 4 mA screen.
Press ENTER to begin editing. Use the arrow keys to select and change the
screen value to the value displayed on the installed ammeter. Press ENTER
to accept the value. After the value is entered, the unit calibrates itself to
ensure it outputs 4 mA. Both the display and the ammeter will display 4 mA.
Pressing EXIT returns to the initial TRIM 4 mA screen, and pressing NEXT
displays the TRIM 20 mA? screen.
Figure 3-14. Trim 4mA