Introduction
Optimize measurement reliability with diagnostics designed for any protocol on any host system.
Thermocouple Degradation Diagnostic monitors the health of a thermocouple loop, enabling
preventative maintenance
Minimum and Maximum Temperature Tracking tracks and records temperature extremes of the
process sensors and the ambient environment
Sensor Drift Alert detects sensor drift and alerts the user
The Hot Backup
™
feature provides temperature measurement redundancy
Refer to the following literature for a full range of compatible connection heads, sensors, and
thermowells provided by Emerson
™
:
Rosemount Volume 1 Temperature Sensors and Accessories
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
,
1.2
Rosemount 3144P revisions
HART Protocol
The initial release of the Rosemount 3144P HART was device revision 3. Each additional revision contains
incremental improvements.
summarizes these changes.
Table 1-1. HART Revisions
Software
release
date
Identify device
Field device driver
Review instructions
NAMUR
software
revision
NAMUR
hardware
revision
HART
software
revision
(1)
1.
NAMUR Software Revision is located in the hardware tag of the device. HART Software Revision can be read using a HART capable
configuration tool.
HART
universal
revision
(2)
2.
Device Driver file names use Device and DD Revision, e.g. 10_07. HART Protocol is designed to enable legacy driver revisions to continue to
communicate with new HART devices. To access this functionality, the new device driver must be downloaded. It is recommended to
download the new device driver to ensure new functionality.
Device
revision
Manual document
number
April-2017
1.2.1
1.0.0
3
7
7
(3)
3.
Rosemount X-well sensor type.
00809-0100-4021
5
5
April-2012
1.1.1
N/A
2
7
6
(4)
4.
HART Revision 5 and 7 Selectable, thermocouple degradation diagnostic, min/max tracking.
5
5
Feb-2007
N/A
N/A
1
5
4
Dec-2003
N/A
N/A
N/A
5
3
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...