![Emerson Rosemount 3101 Reference Manual Download Page 40](http://html.mh-extra.com/html/emerson/rosemount-3101/rosemount-3101_reference-manual_104699040.webp)
28
Reference Manual
00809-0100-4840, Rev CB
February 2015
4.3.3
Setting the bottom reference (on the 3101)
Screen display:
b.rEF
Defaults:
8.000 (m), 26.24 (ft.), 314.9 (in.)
Note
for a map of the programming menu structure and how to access all
the menu options.
To change the bottom reference (b.rEF) setting
1.
If entering the menu system from the PV display, press the green button
to indicate
the “b.rEF” menu option (see the above note).
2.
Press the blue button
to enter the menu for b.rEF. The display indicates the present
b.rEF value.
3.
If this value is correct, press the red button
and then press the green button
to get
to the next menu option. Otherwise, continue with step (
4.
Press the blue button
to start editing. The first digit flashes to indicate it can be
edited.
5.
Press the green button
repeatedly to edit the flashing digit.
6.
Press the blue button
to move to the next digit. The digit flashes to indicate it can be
edited.
7.
Repeat steps (
) until the last digit is flashing, and edited as required.
8.
Press the blue button
to confirm the new b.rEF value. None of the digits should now
be flashing.
9.
Press the red button
to save the new value if it is correct, or press the blue button
to
not save. Afterwards, depending on the button pressed, either the “b.rEF” menu or the
next menu appears.
4.3.4
Setting 4 mA and 20 mA levels (on the 3101)
Screen display:
4 and 20
4 mA level defaults:
0.000 (m), 00.00 (ft.), 000.0 (in.)
20 mA level defaults:
7.500 (m), 24.60 (ft.), 295.2 (in.)
The 4 mA level may be set above or below the 20 mA level to suit the monitoring or control
equipment.
Note
To set the 4 and 20 mA levels by ranging the transmitter to a fixed target, such as the level in the
tank at any particular time, skip these menu options by pressing the green button
twice to get
to the next menu option.
Summary of Contents for Rosemount 3101
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Page 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Page 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Page 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Page 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Page 237: ......
Page 238: ......
Page 239: ......