Quick Installation Guide
00825-0100-4738, Rev BA
October 2009
Rosemount 3095FB
3
S
TEP
1: M
OUNT
THE
T
RANSMITTER
Figure 1. Using a Mounting Bracket
Liquid Flow Applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Mount the transmitter so that the drain/vent
valves are oriented upward.
Gas Flow Applications
1. Place taps in the top or side of the line.
2. Mount beside or above the taps.
Steam Flow Applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Fill impulse lines with water.
Panel Mount
(1)
(1)
Panel bolts are customer supplied.
Pipe Mount
Flow
Flow
Flow