Recommended actions
The FD_RECOMMEN_ACT parameter displays a text string that will give a recommended course of action
to take based on which type and which specific event of the alert is active, see
.
Table 6-12. Recommended Actions for Alerts
Alert Type
Description
Recommended Action
Failure
Software failure
The software is corrupt. Variable status is set to BAD.
1. Restart the device.
2. Contact Emerson Automation Solutions /Rosemount
TankGauging service department.
Database error
The device has detected an error in the measurement
configuration database.
1. Load default database to the device.
2. Restart the device.
3. Reconfigure the device.
Auxiliary Device error
Replace the auxiliary device (Rosemount 2240S
transmitter).
Electronics failure - Main board
The device has detected an irreversible electronics error.
1. Replace the device.
Electronics failure - FF I/O board
The device has detected an irreversible electronics error.
1. Replace the device.
Memory failure - FF I/O board
Configuration data has been corrupted or pending
configuration changes have been lost due to loss of power
before storage could complete.
Default values are loaded into the faulty block. Potential
errors in stored data may cause unwanted behavior. The
device is not in service (OOS) and status for all variables is
BAD. Device recovery is possible.
1. Do a factory reset – FF I/O Board.
2. If error persists, it may indicate a faulty memory chip.
Replace the transmitter head.
Internal communication failure
Communication between the Rosemount 2240S Multi-input
Temperature Transmitter and the FF I/O board has been lost.
The device holds the last known measurement with status
BAD.
1. Restart Device
2. Replace the transmitter head
Summary of Contents for Rosemount 2240S
Page 2: ......
Page 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Page 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Page 193: ......