Daisy-chain connection
You may use the daisy-chain option in order to connect the Rosemount 2230 to other field devices on the
Tankbus:
1. Unscrew and remove all six screws on the front of the Rosemount 2230. Remove the cover carefully.
Take care of the locking device for the weather protection hatch.
Note
Do not disconnect the cables between the display front and the circuit board.
2. Disconnect the termination jumper from the X3 terminal, see
.
Note
Ensure that a terminator is enabled on the last device that is connected to the Tankbus.
3. Run the new Tankbus cable into the Rosemount 2230 compartment through a suitable gland.
4. Connect the outgoing Tankbus wires to the X2-out and X3-out terminals as shown in
5. Connect the cable shield to the X1 terminal.
6. Replace the cover. Make sure the sealing and the locking device for the weather protection hatch are
placed in the correct positions.
7. Firmly tighten the six screws on the front cover.
Figure 3-7. Daisy-chain wiring
the Rosemount 2230 can be daisy-chained to other field devices via the
Tankbus.
Figure 3-8. Wiring diagram for Rosemount 2230
X3: out
X2: out
X1: Cable Shield
Rosemount 2230
Rosemount 2410
Rosemount 5900
Rosemount 2240S
Tankbus
Shield Wire
connected at
power supply
Built-in
terminator
enabled on the
last device
Summary of Contents for Rosemount 2230
Page 1: ...Reference Manual 00809 0100 2230 Rev CA July 2017 Rosemount 2230 Graphical Field Display ...
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 2230 Rev CA Title Page July 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2230 Rev CA Introduction July 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2230 Rev CA Overview July 2017 Overview ...
Page 44: ...34 Reference Manual 00809 0100 2230 Rev CA Installation July 2017 Installation ...
Page 154: ...144 Reference Manual 00809 0100 2230 Rev CA Index July 2017 Index ...
Page 155: ......