112
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
June 2012
Specifications and Reference Data
Shipboard Approvals
Standard
Standard
SBS
American Bureau of Shipping
★
Display and Interface Options
Standard
Standard
M4
(8)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Transient Protection
Standard
Standard
T1
(9)
Transient terminal block
★
Manifold for Remote Mount Option
Standard
Standard
F2
3-Valve Manifold, Stainless Steel
★
F6
5-Valve Manifold, Stainless Steel
★
PlantWeb Control Functionality
Standard
Standard
A01
(10)
F
OUNDATION
fieldbus Advanced Control Function Block Suite
★
PlantWeb Diagnostic Functionality
Standard
Standard
D01
F
OUNDATION
fieldbus Diagnostic Suite
★
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
Standard
WA3
User Configurable Transmit Rate, 2.4 GHz WirelessHART
★
Antenna and SmartPower
Standard
Standard
WP5
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Low Power Output
Standard
Standard
C2
(11)
0.8-3.2 V dc Output with Digital Signal Based on Hart Protocol
★
Alarm Limit
Standard
Standard
C4
(12)
NAMUR Alarm and Saturation Levels, High Alarm
★
NAMUR Alarm and Saturation Levels, Low Alarm
★
Hardware Adjustments
Standard
Standard
DZ
Digital Zero Sensor Trim Configuration Button
★
Ground Screw
Standard
Standard
V5
(13)
External Ground Screw Assembly
★
Typical Model Number: 2051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
(1) Not available for Primary Element Technology C.
(2) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Not available with Primary Element Technology P.
(5) Not available with F
OUNDATION
fieldbus (Output Code F) or Profibus (Output Code W).
(6) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(7) Not available with Low Power code M.
(8) Available only with output code W - Profibus PA.
(9) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(10) Only valid with F
OUNDATION
fieldbus Output Code F.
(11) Not available with F
OUNDATION
fieldbus (Output Code F) or Profibus (Output Code W).
(12) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(13) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Table A-9. Rosemount 2051CFC Compact Flowmeter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Summary of Contents for Rosemount 2051 Wireless Series
Page 2: ......
Page 12: ...4 Reference Manual 00809 0100 4102 Rev AA Section 1 Introduction June 2012 Introduction ...
Page 32: ...24 Reference Manual 00809 0100 4102 Rev AA Section 2 Configuration June 2012 Configuration ...
Page 110: ......
Page 113: ......
Page 117: ...iv Reference Manual 00809 0100 4100 Rev AA Title Page June 2012 ...
Page 123: ...x Reference Manual 00809 0100 4100 Rev AA Table of Contents June 2012 Table of Contents ...
Page 167: ...44 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 168: ...45 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 169: ...46 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 249: ......