Emerson Rosemount 0065 Quick Start Manual Download Page 11

Quick Start Guide

11

August 2017

EAC – Belarus, Kazakhstan, Russia

EM

Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.GB05.B.00289
Markings: 1Ex d IIC T6…T1 Gb X 

Special Condition for Safe Use (X): 

1. See certificate for special conditions.

IM

Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.GB05.B.00289
Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb X

Special Condition for Safe Use (X): 

1. See certificate for special conditions.

Korea

EP

Korea Explosionproof/Flameproof
Certificate: 13-KB4BO-0560X
Markings: Ex d IIC T6…T1; T6(–50 °C 

 T

amb

 

 +40 °C), T5…T1(–50 °C 

 T

amb

 

 +60 °C) 

Special Condition for Safe Use (X): 

1. See certificate.

Combinations

KD

Combination of E1, E5, and E6

K1

Combination of E1, I1, N1, and ND

KM

Combination of EM and IM

Summary of Contents for Rosemount 0065

Page 1: ...Quick Start Guide 00825 0200 2654 Rev DC August 2017 Rosemount 0065 0185 Sensor Assembly ...

Page 2: ...s certifications WARNING Explosions could result in death or serious injury Installation of this transmitter in an explosive environment must be in accordance with the appropriate local national and international standards codes and practices Conduit cable entries Unless marked the conduit cable entries in the transmitter housing use a 1 2 14 NPT thread form Entries marked M20 are M20 1 5 thread f...

Page 3: ... the unused white lead in a manner that prevents shorting to the ground For 2 wire systems connect both sets of leads Flying leads and spring loaded adapter termination codes 0 1 or 3 only Single element Dual element Terminal block termination code 2 and 4 Single element Dual element Red White White Red Red Red Green Blue Blue Black 3 4 1 6 Red Red White White 6 1 3 4 1 2 3 4 5 6 4 5 6 1 2 3 Red R...

Page 4: ...mocouple Characteristics Type Alloys wire color Sheath material Temp range C Limits of error interchangeabilityDIN EN 60584 2 Tolerance class J Fe black Cu Ni white 1 4541 321 SST 40 to 375 375 to 750 1 5 C 0 004 t 1 K Ni Cr green Ni Al white 2 4816 Alloy 600 40 to 375 375 to 1000 1 5 C 0 004 t 1 N Ni Cr Si pink Ni Si white 2 4816 Alloy 600 40 to 375 375 to 1000 1 5 C 0 004 t 1 E Ni Cr violet Cu N...

Page 5: ...t 248 Rosemount 644 Head or field mount transmitters Rosemount IP68 or IP65 connection heads Sensor with flying leads terminal block or spring loaded adapter Extensions Rosemount 644 with LCD display meter Rosemount 3144 40 mm 25 mm L 16 mm N N N L L N dimension measures from thread engagement point 11mm 11 mm ...

Page 6: ...Sensor with flying leads or terminal block Threaded and flanged tubular thermowells Rosemount644with LCD display meter 40 mm Head or field mount transmitters N U U N 25 mm NAMUR NAMUR For straight threading N dimension references bottom of hex For tapered threading N dimension referencesthread engagement point bottom of thread U N U GB GN ...

Page 7: ...aded or flanged barstock thermowells Rosemount 3144 Stand alone extensions Rosemount 248 Rosemount 644 Rosemount IP 68 or IP 65 connection heads Rosemount 644 with LCD display meter 40 mm Head or field mount transmitters 11mm L 11 mm 16 mm N 11 mm 11 mm 60 mm U U U 60 mm L L N dimension measures from thread engagement point This dimension is 80 mm for Class 1500 and Class 2500 flanges N N 25 mm T ...

Page 8: ...arkings must be suitable for the area classification gas and temperature class This information is clearly defined in the respective codes 3 4 Hazardous locations certifications USA E5 FM Explosion proof and Dust Ignition proof Certificate FM17US0170X Standards FM Class 3600 2011 FM Class 3611 2004 FM Class 3615 2006 FM Class 3810 2005 ANSI NEMA 250 1991 Markings XP CL I Div 1 GP B C D DIP CL II I...

Page 9: ...gree of ingress protection of at least IP20 N1 ATEX Type n Certificate BAS00ATEX3145 Standards EN 60079 0 2012 EN 60079 15 2010 Markings II 3 G Ex nA IIC T5 Gc 40 C Ta 70 C ND ATEX Dust Certificate FM12ATEX0065X Standards EN 60079 0 2012 A11 2013 EN 60079 31 2014 Markings II 2 D Ex tb IIIC T130 C Db 40 C Ta 70 C Special Conditions for Safe Use X 1 See certificate for ambient temperature range 2 Th...

Page 10: ...aint is ordered through a special option code contact the manufacturer for more information Brazil E2 INMETRO Flameproof Certificate UL BR 13 0535X Standards ABNT NBR IEC 60079 0 2008 Corrigendum 1 2011 ABNT NBR IEC 60079 1 2009 Corrigendum 1 2011 Markings Ex d IIC T6 T1 Gb T6 T1 50 C Ta 40 C T5 T1 50 C Ta 60 C Special Conditions for Safe Use X 1 See product description for ambient temperature lim...

Page 11: ...nion EAC Intrinsic Safety Certificate RU C US GB05 B 00289 Markings 0Ex ia IIC T6 Ga X Ga Gb Ex ia IIC T6 X 1Ex ia IIC T6 Gb X Special Condition for Safe Use X 1 See certificate for special conditions Korea EP Korea Explosionproof Flameproof Certificate 13 KB4BO 0560X Markings Ex d IIC T6 T1 T6 50 C Tamb 40 C T5 T1 50 C Tamb 60 C Special Condition for Safe Use X 1 See certificate Combinations KD C...

Page 12: ...rs manufactured by Rosemount Inc 8200 Market Boulevard Chanhassen MN 55317 9685 USA to which this declaration relates is in conformity with the provisions of the European Union Directives including the latest amendments as shown in the attached schedule Assumption of conformity is based on the application of the harmonized standards and when applicable or required a European Union notified body ce...

Page 13: ...armonized Standards EN60079 0 2012 A11 2013 EN60079 15 2010 Baseefa16ATEX0101X Intrinsic Safety Certificate Equipment Group II Category 1 G Ex ia IIC T5 T6 Ga Harmonized Standards EN60079 0 2012 A11 2013 EN60079 11 2012 RoHS Directive 2011 65 EU Harmonized Standard EN 50581 2012 ATEX Notified Bodies FM Approvals Notified Body Number 1725 1151 Boston Providence Turnpike P O Box 9102 Norwood MA 0206...

Page 14: ...bly O O O O O O ༣փ㓴Ԧ Housing Assembly O O O O O O Րᝏಘ㓴Ԧ Sensor Assembly O O O O O O ᵜ㺘Ṭ ᦞ SJ T11364 Ⲵ㿴ᇊ㘼ࡦ This table is proposed in accordance with the provision of SJ T11364 O Ѫ䈕䜘ԦⲴᡰᴹ 䍘ᶀᯉѝ䈕ᴹᇣ 䍘Ⲵਜ਼䟿 վҾ GB T 26572 ᡰ㿴ᇊⲴ䲀䟿㾱 O Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Ѫ 䈕䜘Ԧᡰ Ⲵᡰᴹ 䍘ᶀᯉ䟼ˈ㠣ቁᴹа 䍘ᶀᯉѝ䈕ᴹᇣ 䍘Ⲵਜ਼䟿儈Ҿ GB T 2...

Page 15: ...Quick Start Guide 15 August 2017 ...

Page 16: ... is a trademark and service mark of Emerson Electric Co Rosemount and Rosemount logotype are trademarks of Emerson National Electrical Code is a registered trademark of National Fire Protection Association Inc NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association All other marks are the property of their respective owners 2017 Emerson All rights reser...

Reviews: