10
user servicing / troubleshooting
Instructions
PRoBlem cAuse solutIoN
Unit will not run. 1. No power to unit. 1. Plug unit in. Check circuit breaker.
2. Switch not on. 2. Place in “ON” position.
3. Switch is faulty. 3. Replace switch.
4. Faulty/broken cord or 4. Perform continuity check, using
motor wire. volt/amp meter.
Unit runs but air 1. Unit has been severely jolted 1. Remove motor and replace
mover makes causing blower wheel to rub damaged motor if necessary.
loud scraping against housing.
noise.
2. Unit has been severely jolted 2. Replace blower wheel.
causing housing to deform.
Unit runs but 1. Severe jolt has bent motor 1. Remove and replace motor.
vibrates shaft causing unit to be out of
excessively. balance.
2. Blower wheel blade damaged. 2. Replace blower wheel if necessary.
3. Dirt build up on one side of 3. Clean blower wheel blades.
Air Mover blower wheel.
Unit runs but 1. Blower wheel is jammed 1. Adjust and replace blower wheel
blower wheel against housing. if necessary.
does not turn.
2. Capacitor wire has broken/ 2. Repair/replace motor
come loose, capacitor has if necessary.
failed.
3. Housing has been damaged 3. Replace unit as necessary.
such that it presses on blower
wheel.
Unit runs briefly, 1. Motor bearings are failing or 1. Replace motor.
then shuts off motor has developed an
on overload. internal electrical fault.
2. Intake grille and/or exhaust 2. Remove obstruction.
grille is obstructed.
Convenience 1. No power to unit. 1. Plug unit in.
outlet not
working. 2. Convenience outlet circuit 2. Reset circuit breaker.
(if equipped) breaker not reset.
!
WARNING: unplug before any disassembly or servicing.
!
WARNING: All disassembly and repairs should be performed by qualified
personnel.
SP7019 3-Speed Air Mover.qxp_SP7019 Air Mover 2/23/17 11:19 AM Page 10