background image

11

REGAL 3F

Item

Description          

Reference

1

Valve plug assembly

181 058

2

O-ring

400 506

3

Diaphragm

142 033

4

Clutch O-ring

400 505

5

Spring

See Table 3

6

Cap O-ring

400 080

7

Screw

403 030

8

Actuator/body O-ring

400 029

9

Truarc ring

406 201

10

Sensing diaphragm

138 369

11

Tightshut washer

461 173

12

Ori

fi

 ce

142 017

13

Ori

fi

 ce O-ring

400 102

With Slam Shut

Type VSX2

Type OS2

14

Circlips

406 153

15

Spring

144 064

16

Valve plug

142 130

17

Slam shut Pu O-ring

400 081

18

Slam shut Pd O-ring

400 074

-

19

Screw

403 028

20

Bypass O-ring

400 501

21

Stem O-ring

-

400 505

22

Diaphragm assembly

181 017

181 027

181105

23

Slam shut assembly

196 433

196 250

196245

Without Slam Shut

24

Bottom O-ring

400 081

Spare parts kit (commissioning spares)

197 480

Table 7. 

Spare Parts

Summary of Contents for REGAL 3F

Page 1: ...ormity with the Pressure Equipment Directive 2014 68 UE PED Name Function Company stamp Date Signature The type REGAL 3F is in conformity with the Pressure Equipment Directive PED 2014 68 UE and is classified under category I Equipment and pipeline situated on the outlet side of the regulator are either not subject to the PED Pu 0 5 bar or subject to Pu 0 5 bar in this case the type Regal 3F is cl...

Page 2: ...m balanced valve plug an orifice An integral bypass slam shut in place of the bottom see D103695X012 manual Depending on set point required A Pd set point adjustment spring A tripping spring set to max A tripping spring set to min A Version with Integral Slam Shut Type OS2 A body a diaphragm actuator A diaphragm balanced valve plug an orifice A slam shut connecting part in place of the bottom A va...

Page 3: ... 520 10 300 1 520 500 1 500 5 1000 2 700 Table 2 Regulator Flow Ranges Table Pd mbar Spring Spring Nominal Min Max Wire Ø Length mm mm code 100 60 140 5 5 165 131 918 160 80 180 6 0 142 539 300 100 320 7 0 167 144 300 500 300 550 8 0 170 131 793 1000 400 1100 10 0 144 035 Table 3 Regulator Set Point Spring Regulator Ranges Table Wire Ø mm Nominal Set Point Nominal Pd VSX2 Springs OS2 Springs mbar ...

Page 4: ...tlet pressures Pressure control is achieved through the actuator diaphragm which receives on the one side the outlet pressure and on the other side the spring load adjusted to the desired value by the set point spring Tight shutoff is ensured by the regulator plug disc pushing on the orifice The regulator can be equipped with a slam shut using a release relay types VSX2 or OS2 In the case of tempo...

Page 5: ...ction and or specific calculations may be supplied according to specific requirements CAUTION All interventions on equipment should only be performed by qualified and trained personnel WARNING The regulator is installed on horizontal recommended or vertical pipeline Version with slam shut the release relay can be situated towards the bottom or the top Installation according to EN12186 or EN12279 r...

Page 6: ...tripping Adjust the setting if necessary see D103695X012 manual Note the set point value on the equipment or mark it on a commissioning document Type OS2 Figure 7 Using the atmospheric valve R2 inject a pressure equal to the pressure required for the regulator 1st release relay stage Set Stage 1 Slam shut valve plug Set Stages 2 and 3 Progressively increase the pressure to reach tripping Adjust th...

Page 7: ...TOMS CAUSE ACTIONS If the outlet pressure increases Internal leak Control the regulator valve plug Control the regulator orifice or contact after sales If the outlet pressure decreases External leak Locate and seal the leak or contact after sales If the outlet pressure is constant The regulator is tightshut Close the impulse isolation valve Open the impulse atmospheric valve Progressively inject p...

Page 8: ...ment spanner for VSX2 Ref 197 226 Regulator Valve plug closed no flow Inlet and outlet valves closed Bleed off outlet pressure Bleed off inlet pressure Unscrew the cap key 6 Unscrew the adjustment screw key 5 Remove the adjustment screw assembly key 5 Unscrew the actuator screws key 3 Remove the cover key 4 Unscrew the main diaphragm assembly key 2 CAUTION Before disassembling the diaphragm not e ...

Page 9: ...om the mechanism box yoke key 16 Remove the connecting part key 18 and the valve axle key 15 Contrôler le clapet de sécurité key 13 Reassembly Perform the above operations in reverse order respect tightening torques Diaphragms to be changed every 6 years or less depending on condition Respect the relief valve setpoint dimension noted during disassembly Replace O rings at each disassembly Lubricate...

Page 10: ...10 REGAL 3F SPARE PARTS Figure 9 Type Regal 3F VSX2 and Type Regal 3F OS2 Spare Parts detail ...

Page 11: ...ut washer 461 173 12 Orifice 142 017 13 Orifice O ring 400 102 With Slam Shut Type VSX2 Type OS2 14 Circlips 406 153 15 Spring 144 064 16 Valve plug 142 130 17 Slam shut Pu O ring 400 081 18 Slam shut Pd O ring 400 074 19 Screw 403 028 20 Bypass O ring 400 501 21 Stem O ring 400 505 22 Diaphragm assembly 181 017 181 027 181105 23 Slam shut assembly 196 433 196 250 196245 Without Slam Shut 24 Botto...

Page 12: ...xpress or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available on request We reserve the right to modify or improve the designs or specifications of our products at any time without notice Emerson Process Management Regulator Technologies Inc does not assume responsibility for the selection ...

Reviews: