VERIFICATION OF REFCON PORTABLE 
MODEM 

 

Installation and verification REFCON portable modem 
 

3.1 

Connect the REFCON Portable modem to the reefers in retriever plug and turn the knob 
clock wise. 

3.2 

Follow the chart for verification (Figure 1) 

3.3 

Final verification is done by the REFCON Application where the actual Container is 

showing with the collected data for the specific reefer

Installation of the REFCON Application 

3.4 

Install the Application on your Android device by following the REFCON Application 
installation guide. 

Figure 1.

 

Install RMM-P and 
wait 5 seconds for 
the LED multi 
status indicator to 

show status

 

Red flash after 6 minutes 
Indicating: Controller not 
supported, or the RS232 
connection is faulty

 

 
 

No flash  

 

Green flash after 6 
minutes – Unit OK

 

 

Yellow blink  
Indicating: OK and Ready to 
communicate with 
controller

 

 

Verify that the controller type 
is supported and verify the 
controller ID 

Verify the functionality of the 
RS232 line and repair if 
required

 

Indicating RS232 
connection is 
interrupted for the 
REFCON Portable 
Modem. 

 

 

Verify the Reefers RS232 plug 
and wiring. Repair if required

 

Verify the modem on another 
unit. Return the modem if 
found faulty

 

Verify that the Container 
shows in the REFCON 
Application

 

Summary of Contents for REFCON

Page 1: ...xel Kiers Vej 5A 8270 Højbjerg Denmark www emerson com T 45 7023 4444 F 45 7023 6044 Copyright Emerson All Rights Reserved REFCON Portable Modem User Manual_1 1 Transportation Solutions Updated 2019 03 12 Author Jens Sarup Page 1 of 6 REFCON Portable Modem User Manual ...

Page 2: ... This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmfu...

Page 3: ...n exposure limits set forth for an uncontrolled environment under the following conditions 1 This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 2 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 1 2 Safety Warnings Caution contains Static Sensitive ...

Page 4: ...trieval plug or with an extension cable depending on the application from here all data is wirelessly sent to REFCON where the data and alarms can be processed by the crew The REFCON Portable Modem can also be used in an application where infrastructure is unavailable which could be on short term charter vessels or on peak season storage areas on terminals in these cases the REFCON Mobile app can ...

Page 5: ...r Android device by following the REFCON Application installation guide Figure 1 Install RMM P and wait 5 seconds for the LED multi status indicator to show status Red flash after 6 minutes Indicating Controller not supported or the RS232 connection is faulty No flash Green flash after 6 minutes Unit OK Yellow blink Indicating OK and Ready to communicate with controller Verify that the controller ...

Page 6: ...1 Transportation Solutions Updated 2019 03 12 Author Jens Sarup Page 6 of 6 Document Revision Record Rev Date Author Brief description of change Pages affected 1 0 060616 JES Original issue All 1 1 120319 JES Updated legislation text All ...

Reviews: