background image

1

DC Power for 
Business-Critical Continuity™

High efficiency eSure

 rectifiers provide dramatic 

reductions in energy costs and advanced features  

for legacy Lorain

®

 A50B50 based DC power systems.

Product Overview

The NetSure

®

 A50B50 DC Power Retrofit provides a unique solution for maintaining and 

upgrading legacy Lorain

®

 DC power systems based on the A50B50 rectifier. Specially 

designed frames mount directly into existing rectifier slots without the need for elec-
trical or mechanical adjustments. These frames accommodate the R48-3500E and 
R48-3200E eSure

 high efficiency rectifiers as well as the standard R48-3200 rectifier.

Two distinct frames are available. Model A50IFRM accommodates a single rectifier 
and controller. Model A50EFRM houses a single rectifier. Each system starts with one 
A50IFRM. The A50EFRM provides growth for up to thirty-six rectifiers in a single system.

The NetSure

®

 A50B50 DC Power Retrofit can be used with or without the original 

A50B50 rectifiers in the same system. The frames contain the necessary connections 
and circuitry to manage the monitoring and alarming of all rectifiers.

The system’s original meter-control-alarm panel can remain in place. Or, if desired, 
the NetSure

® 

controller can be used instead, providing significant enhancements over 

existing electronics including programmable alarming, customer I/O and local/remote 
access over Ethernet.

Application

The NetSure

®

 A50B50 DC Power Retrofit is designed for use in existing Lorain

®

 DC 

power Systems containing A150CAB or A200CAB rectifier shelves designed initially to 
accommodate A50B50 rectifiers. The NetSure

®

 A50B50 DC Power Retrofit can be used 

in conjunction with or in place of A50B50 rectifiers with the following specification 
numbers: 486522200, 486523401, 
486523403, 486523406, 486524801, 
486526401.

Additional information

Additional specification, engi-
neering and installation 
information may be obtained by 
requesting SAG588250400 
(system application guide) and 
UM588250400 (User Manual). 

NetSure

®

 A50B50

DC Power Retrofit

Key Features

 

Increases efficiency from 85% 
to >96%; reduces energy 
consumption by >11%; 
reduces heat loss by >73%

 

NetSure

®

 reliability improves 

mean time between failure 
(MTBF)

 

Constant power limiting 
feature increases current 
capacity to 73 amps per 
rectifier

 

Plugs right into A50B50 
rectifier slot without any 
electrical or mechanical 
adjustments to existing shelf 
or system

 

Operates with or without 
original A50B50 rectifiers in 
same system

 

Enhanced controller features 
including single point 
adjustment and remote access 
via Ethernet

127D-NSA50B50 / 0211