background image

4

PENBERTHY 

MODEL GSA ANOLODER FOR AN-FO (AMMONIUM NITRATE - FUEL OIL) BLASTING

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TABLE 2

Problem

Cause

Solution

Anoloder cannot be turned 
on or off

1. plugged piston valve

1. take ejector apart and clean as 
described in previous section

2. plugged control valve

2.  manipulate control valve piston, wash 

in water and blow out with air

Anoloder operated but no 
AN-FO exits loading hose

1.  plugged ejector inlet or loading 

hose

1.  clean anoloder as described in 

previous section - be sure air lubricator 
has been removed from air hose

Sharply reduced loading rate

1. plugged air strainer

1. remove air strainer and clean

2. dirt in ejector body

2.  take ejector apart and clean as 

described in previous section

3.  partially plugged ejector inlet 

or loading hose

3.  clean anoloder as described in 

previous section - be sure air lubricator 
has been removed from air hose

4.  air pressure at ejector is too 

low

4.  increase air pressure to recommended 

range (Section 5)

6.2 Troubleshooting

7 DISPOSAL AT END OF USEFUL LIFE

Penberthy Model GSA anoloders are used in 
a variety of fluid applications. By following the 
appropriate federal and industry regulations, the 
user must determine the extent of preparation 
and treatment the Model GSA anoloder must 
incur before its disposal. A Material Safety Data 
Sheet (MSDS) may be required before disposal 
services accept certain components.
Metal, glass and polymers should be recycled 
whenever possible. Refer to order and the 
applicable technical data sheet for materials of 
construction.

8 TELEPHONE ASSISTANCE

If you are having difficulty with your Model 
GSA anoloder, contact your local Penberthy 
distributor. So that we may assist you more 
effectively, please have as much of the 
following information available as possible 
when you call:

- Model #
- Name of the company from whom you 

purchased the Model GSA anoloder

- Invoice # and date
- Process conditions (pressure, flow rates, tank 

shape, etc)

- A brief description of the problem
- Trouble shooting procedures that failed

If attempts to solve your problem fail, you may 
request to return your Model GSA anoloder 
to the factory for intensive testing. You must 
obtain a Return Authorization (R.A.) number 
from Emerson before returning anything. 
Failure to do so will result in the unit being 
returned to you without being tested, freight 
collect. To obtain an R.A. number, the following 
information (in addition to that above) is 
needed:

- Reason for return
- Person to contact at your company
- 'Ship-to' address

There is a minimum charge for evaluation 
of non-warranty units. You will be contacted 
before any repairs are initiated should the cost 
exceed the minimum charge. If you return a 
unit under warranty, but it is not defective, the 
minimum charge will apply.

Summary of Contents for PENBERTHY GSA

Page 1: ... at its expense Emerson shall not be liable for loss damage or expenses related directly or indirectly to the installation or use of its products or from any other cause or for consequential damages It is expressly understood that Emerson is not responsible for damage or injury caused to other products buildings personnel or property by reason of the installation or use of its products This is Eme...

Page 2: ...he air flow stream by bleeding a portion of the air flow which allows an internal piston to move and open the air orifice in the ejector Loading hose static resistant plastic hose directs the air and powder mixture into the drilled hole Carrying strap canvas strap makes the anoloder portable The anoloder is light enough that most operators can carry the units to various work and powder loading are...

Page 3: ...oad properly if air blows freely out loading hose 5 2 Filling and operating Pour the AN FO into the canister to within a few inches of the top approximately 25 lbs or up end the entire bag and leave it in the container Insert loading hose into drill hole to predetermine the length of hose needed to reach the bottom of the hole Back the hose out of the hole one to four feet from the bottom Safety i...

Page 4: ...ust incur before its disposal A Material Safety Data Sheet MSDS may be required before disposal services accept certain components Metal glass and polymers should be recycled whenever possible Refer to order and the applicable technical data sheet for materials of construction 8 TELEPHONE ASSISTANCE If you are having difficulty with your Model GSA anoloder contact your local Penberthy distributor ...

Page 5: ... marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions...

Reviews: