Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not 

1. Reversing switch in neutral position.

1. Make sure reversing switch position is all the way to

start.

one side.

2. Fuse or circuit breaker blown.

2. Check main and branch circuit fuses or circuit 

breakers.

3. Loose power line connections to the fan, or 

3. Check line wire connections to fan and switch

loose switch wire connections in switch housing.

wire connections in the switch housing.

2. Fan sounds 

1. Blades not attached to fan.

1. Attach blades to fan before operating.

noisy.

2. Loose screws in motor housing.

2. Check to make sure all screws in motor housing are 

snug (not over-tight).

3. Screws securing fan blade flanges to motor are

3. Check to make sure the screws which attach the fan

loose.

blade flanges to the motor are tight.

4. Wire connectors inside switch housing 

4. Check to make sure wire connectors in switch housing

rattling.

are not rattling against each other or against the 
interior wall of the switch housing.

5. Screws holding flanges to blades are loose.

5. Tighten securely.

3. Fan wobbles

1. Screws securing fan blade flanges to motor are 

1. Check to be sure screws which attach the fan blade 

or shakes.

loose.

flanges to the motor are tight.

2. Fan blade flanges not seated properly.

2. Check to be sure the fan blade flanges seat firmly and

uniformly to the surface of the motor. If flanges are
seated incorrectly, loosen the flange screws and
retighten according to the procedure in the section on
"How to Put Your Ceiling Fan Together".

3. Mounting plate and/or ceiling outlet box is not

3. Tighten the mounting plate screws to the outlet box,

securely fastened.

and/or secure outlet box.

4. Fan blades out of balance.

4. Interchanging an adjacent (side-by-side) blade pair can 

redistribute the weight and result in smoother operation.

7

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for twenty years from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Company will refund the actual purchase
price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and
shipping of the product to Emerson Company.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

!

Summary of Contents for Northwind TRADITIONAL SNUGGER CF704SAB02

Page 1: ...l You should record this data above and keep it in a safe place for future use TRADITIONAL SNUGGER Ceiling Fan Owner s Manual Part No F40BP70800006 Form No BP7080 6 by Model No CF705SAB02 CF704SAB02 CF705SPB02 CF704SPB02 CF705SWW02 CF704SWW02 CF705SW02 CF704SW02 CF705SAW02 CF704SAW02 Net Weight 11 0 Lbs Net Weight 14 0 Lbs ...

Page 2: ...aced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury...

Page 3: ...ly those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING WARNING Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 vol...

Page 4: ...bracket See Figure 4 Securely tighten the four 3 16 locknuts supplied onto the threaded studs then try to shake the motor bracket to ensure that the assembly is tight Proceed to section HOW TO PUT YOUR CEILING FAN TOGETHER How to Hang Your Ceiling Fan CEILING FLOOR AT LEAST 7 Figure 1 4 OUTLET BOX LEVELING WASHER IF REQUIRED HOOK PLAIN WASHER SUPPLIED MOUNTING SCREWS SUPPLIED WITH OUTLET BOX MOUNT...

Page 5: ...Fan WHITE SUPPLY NEUTRAL BLACK FAN WIRE WHITE FAN WIRE GREEN GROUND WIRE BLUE FAN WIRE WIRE CONNECTORS BLACK SUPPLY HOT SUPPLY GROUNDING CONDUCTOR WIRE Figure 5 5 To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe oper...

Page 6: ...NTROL SWITCH 6 THREE SPEED 1st Pull High 2nd Pull Medium 3rd Pull Low 4th Pull OFF To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING NOTE Take care not to scratch the fan housing when installing the blade assemblies 4 You have now completed the assembly of your new ceiling fan 1 4 20 x 1 2 SCREW BLADE FLANGE BLADE Figure 8 Maintena...

Page 7: ... practical or possible within a reasonable time and no replacement can be provided Emerson Company will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but you are responsible for all costs or removal reinstallation and shipping of the product to Emerson Company How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEI...

Page 8: ... Parts Bag 761555 2 761555 761555 1 761555 761555 761555 2 761555 761555 1 761555 761555 Containing Blade Hardware Hanging Hardware Wood Pendant Coupling 5 Harness Wiring 761543 761543 761543 761543 761543 761529 761529 761529 761529 761529 Owner s Manual BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 3 2 1 5 4 HARDWARE BAG NOT SHOWN Printed in Taiwan Par...

Reviews: