7. Insert the black and white wires through

the lockwasher(8) and hex nut(9)
supplied. Firmly tighten the hex nut to
secure the light kit fitter(7) to the switch
cup(1) (Figure 2).

8. Connect the white wire from the switch

cup to the white wire of the light fitter
(Figure 2). Connect the blue wire from
the switch cup to the black wire of the
light fitter. Use U.L. listed wire
connectors (previously removed in
Step 5) to make connections (Figures 2
and 3).

9. Carefully tuck all wires and splices

into the switch cup(1). (Figure 2.)

10. Connect the motor connector(4) to the

switch cup connector(5).

(3) SCREWS

(5) SWITCH CUP
      CONNECTOR

(2) COVER PLATE

(6) WIRE
      CONNECTORS

WHITE WIRES

(1) SWITCH
      CUP

BLACK WIRE

FAN SWITCH
CHAIN

(8) LOCKWASHER

(9) HEX NUT

(7) LIGHT FITTER

BLUE WIRE

(4) MOTOR
      CONNECTOR

3

6

(3) SCREWS

(6) CENTER SCREW

(1) SWITCH
      CUP   

(4) MOTOR
     CONNECTOR

(2) COVER PLATE

(5) SWITCH CUP
      CONNECTOR

Figure 1

Installation on Emerson

Fans with Modular

(Detachable)

Switch Cups

1. Remove all parts and parts packages

from the carton.

2. On the ceiling fan, remove the switch

cup(1) from the cover plate(2) by
removing the three screws(3) around
the side of the switch cup (Figure 1).

3. Disconnect the motor connector(4) from

the switch cup connector(5) (Figure 1).

4. Remove the center screw(6) from the

switch cup (Figure 1).

5. Carefully locate the white and blue

wires (labeled either "L" or "LIGHT") in
the switch cup. Remove and retain the
wire connectors(6) from the wires
(Figure 2).

6. Insert the black and white wires from

the light fitter(7) through the center hole
in the switch cup (Figure 2) and thread
the switch cup tightly onto the light
fitter. Hold wires taut while installing
switch cup to prevent the wires from
twisting. 

Figure 2

Figure 3

To avoid possible fire or electrical
shock, make certain no bare wire
strands are exposed outside wire
connectors. 

WARNING

!

NOTE: This equipment has been
tested and found to comply with
part 18 of the FCC Rules. This
equipment generates, uses and can
radiate radio frequency energy and
if not installed and used in
accordance with the instructions,
may cause harmful interference to
radio communications. However,
there is no guarantee that
interference will not occur in a
particular installation. If this
equipment does cause harmful
interference to radio or television
reception, which can be determined
by turning the equipment OFF and
ON, the user is encouraged to
correct the interference by one or
more of the following measures:

-

Reorient or relocate the receiving
antenna.

-

Increase the separation between
the equipment and receiver.

-

Connect the equipment into an
outlet on a circuit different from
that to which the receiver is
connected.

Changes or modifications not
expressly approved by the party
responsible for compliance could
void the user’s authority to operate
the equipment.

Replacement of the

Fluorescent Bulbs

1. Remove the pendants from the fan and

light switch chains (Figure 7).

2. Hold the glass shade(1) securely while

removing the finial nut(2), glass
cap(3), hex nut and the guide plate(4)
(Figure 7).

3. Carefully place the glass shade, finial

nut, glass cap, hex nut and guide plate
in a safe place while replacing the
bulb(s).

NOTE: Use only replacement 13-watt
GU24 fluorescent bulb(s).

4. Install the replacement bulb in

accordance with the “Installation of
Fluorescent Bulbs and Glass Shade”
section, on Page 5.

THREADED 
NIPPLE

LIGHT FITTER

13-WATT GU24 
FLUORESCENT BULB

(1) GLASS
SHADE

FAN SWITCH CHAIN

LIGHT FITTER CHAIN

(4) GUIDE PLATE

FAN SWITCH 
PENDANT

(2) FINIAL NUT

LIGHT SWITCH 
PENDANT/COUPLING

(3) GLASS CAP

HEX NUT

Figure 7

Summary of Contents for LK59FOM

Page 1: ...e center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation ...

Page 2: ...re electricity is turned off at the main fuse or circuit breaker box before wiring 2 Make certain no bare wires are exposed outside the wire connectors 3 All wiring must conform to national and local electrical codes 4 Follow the recommended instructions for the proper method of wiring your new light fixture If you feel you do not have enough electrical wiring knowledge or experience have your lig...

Page 3: ...m twisting Figure 2 Figure 3 To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors WARNING NOTE This equipment has been tested and found to comply with part 18 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interferenc...

Page 4: ...RNING To avoid possible electric shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring WARNING 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch housing Remove and retain the wire connectors 3 from the wires 6 Connect the white wire from the ceiling fan to the white wire of the light fitter 6 Connect the blue wire from the c...

Reviews: