Chapter 5 iCOM Controller 63
Liebert.PEX2 Series Air Conditioner User Manual
Parameters
Default
Description
S609 CAL DS2
29°C
Sum of the calibrated value and return air humidity measured by digital scroll 2NTC
sensor. This value is engaged in the calculation
S610
OUT SNS
°C
Outdoor Sensor
S611
CAL OUT
+0.0K
Calibrated Outdoor Sensor
S613
TEMP A
+0.0K
Calibrated value of temperature sensor A
S614
CAL A
°C
Calculated value corresponding to temperature sensor A
S615
HUM A
+0.0%
Calibrated value of humidity sensor A
S616
CAL A
44.0%
Calculated value corresponding to humidity sensor A
S617
TEMP B
TH
Calibrated value of temperature sensor B
S618
TYPE B
+0.0K
Type of temperature sensor B
S619
CAL B
°C
Calculated value corresponding to temperature sensor B
S620
HUM B
+0.0%
Calibrated value of humidity sensor B
S621
CAL B
44.0%
Calculated value corresponding to humidity sensor B
S622
TYPE C
TH
Type of temperature sensor C
S624 FC SNSR
-
Free cooling temperature sensor. PTC or NTC sensor can be configured according to the
actual configuration
S625
FC SNSR
+0°C
Calibrated value of free cooling temperature sensor
S626
CAL FC
°C
Calculated value of free cooling temperature sensor
S627
SUP SNSR
NTC
Air supply temperature sensor. PTC or NTC sensor can be configured
S628
SUP TEMP
+0.0K
Calibrated value of air supply temperature sensor
S629
CAL SUP
°C
Calculated value of air supply temperature sensor
S630
TEMP C
+0.0K
Calibrated value of temperature sensor C
S631
CAL C
°C
Calculated value of temperature sensor C
S632
HUM C
+0.0%
Calibrated value of humidity sensor C
S633
CAL C
%
Calculated value of humidity sensor C
5.7.8 NETWORK SETUP
The NETWORK SETUP menu is used to set the parameters when the system is in a network subject to the monitoring
of a host. See Table 5-27 for parameter descriptions.
Table 5-27 Descriptions of NETWORK SETUP parameters
Parameters
Default
Setting range
Description
S802
#UNITS
1
1 ~ 32
Range: 1 ~ 32
S803
TEAMWORK
No
No, 1, 2
Range: No, 1, 2
S824
MON ADD
3
1 ~ 99
Monitoring address No. of the unit
S825
MON T.O.
No
No, 1, 2
Monitoring Timeout
S825
MON H.S.
3
1 ~ 99
Monitoring Handshake
S831 CS CTRL
No
Save, Load,
No
Save the parameter set through MON ADD to the iCOM controller.
‘No’ means not saved
S831
CS STAT
Change
Change, Valid
Indication of the saving state of the parameter set through MON
ADD. ‘Change’ means that the parameter is changed but not saved.
‘Valid’ means that the setting is valid and saved
S832 NW CTRL
No
Save, Load,
No
Save the parameter set through U2U GRP to the iCOM controller.
‘No’ means not saved
S832
NW STAT
Valid
Change, Valid
Indication of the saving state of the parameter set through U2U
GRP. ‘Change’ means that the parameter is changed but not saved.
‘Valid’ means that the setting is valid and saved
S835 MON PROT
Vlcty
Vlcty, HN,
IGM, No
Host monitoring protocol setting. Range: Vlcty (Velocity uses
intelligent card), HN (Hironet), IGM (ECA2), No
S836 IP #1
192
S836 IP #2
168
S836 IP #3
254
S836 IP #4
1
-
Set IP address
S837 NM #1
255
S837 NM #2
255
S837 NM #3
255
S837 NM #4
0
-
Set subnet mask
Summary of Contents for Liebert PEX Series
Page 1: ...User Manual ...
Page 5: ......