background image

8

OUTLET BOX

BLACK SUPPLY WIRE

BLACK/WHITE RECEIVER WIRE

BLACK FAN WIRE

BLUE FAN WIRE

BLUE RECEIVER 
WIRE

YELLOW FAN WIRE

YELLOW RECEIVER WIRE

CEILING COVER

WHITE RECEIVER WIRE

WHITE FAN WIRE

WIRE CONNECTOR

RECEIVER

WHITE SUPPLY
WIRE

SUPPLY 
GROUND
WIRE (GREEN 
OR BARE)

HANGER BALL
GROUND WIRE
(GREEN)

HANGER BRACKET
GROUND WIRE
(GREEN)

HANGER BRACKET

BLACK RECEIVER WIRE

OPEN 

PORTION OF 

RECEIVER 

HERE

Figure 15

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box
before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible
electrical shock.

WARNING

!

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician. 

CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan and light kit or receiver.

1.

Pull the wire leads, coming from the end of the
downrod, and the supply wires through the open
side of the hanger bracket. (Figure 15).

2.

Position the SW105 Receiver (supplied) in the
ceiling cover so that the flat side of the receiver
faces up and the open portion of the receiver is to
the right, as shown in Figure 15.

3.

Using wire connectors (supplied), make wiring
connections as follows (Figure 15 and 16):

a.

Connect the white fan wire and the white supply
wire to the white receiver wire (AC IN/
MOTOR N).

b.

Connect the black fan wire to the black receiver
wire (TO MOTOR L).

c.

Connect the black supply wire to the black/white
receiver wire (AC IN L).

d.

Cut off the ends of the blue and yellow receiver
wires and strip back insulation 1/2-inch from the
ends of the wires (if required, these ends may
already be stripped).

e.

Connect the blue fan wire to the blue receiver
wire (BOTTOM LIGHT).

f.

Connect the orange fan wire to the yellow
receiver wire (UPPER LIGHT).

g.

Connect the green ground wires from the
hanger bracket and the hanger ball to the supply
ground wire (bare or green).

How to Wire Your Ceiling Fan

U.L. Model No.: CF820

Summary of Contents for LA FAYETTE CF820ORB00

Page 1: ...AD AND SAVE THESE INSTRUCTIONS Part No F40BP73510000 Form No BP7351 U L Model No CF820 Net Weight 37 0 Lbs Model Numbers LA FAYETTE Ceiling Fan Owner s Manual CF820ORB00 Oil Rubbed Bronze CF820PW00 Pewter ...

Page 2: ...The longer downrod 12 furnished with the ceiling fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 6 downrod supplied is to be used for shorter ceilings 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades 6 Follow the recommended instructions for the proper method of wiring your ceili...

Page 3: ... injury or property damage WARNING WARNING 1 Open styrofoam unit containing fan Remove upper and center sections of styrofoam unit Remove parts and check to see that you have received the following a One Fan Motor and Housing Assembly b One Ceiling Cover c Five Fan Blades d Five Flange Assemblies e One Coupling Cover f One Hanger Bracket g One 12 Downrod Hanger Ball Assembly h One 6 Downrod i One ...

Page 4: ... 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 lbs or Less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and ma...

Page 5: ...pin connector from the uplight kit assembly connect the fan motor housing white wire single pin connector to the white wire single pin connector from the uplight kit assembly Figure 4 Be sure all wire connectors are fully engaged To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign object...

Page 6: ...s shade and slide into one of the legs of the decorative lower scroll 22 Assemble the scroll end and lower scroll using the two screws supplied Assemble the remaining two legs and ends as described Figure 10 23 Slide the decorative upper scroll over the downrod engaging the pin of the decorative lower scroll into one hole of the decorative upper scroll and secure screw in collar of the decorative ...

Page 7: ...ed electrician if in doubt WARNING 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 14 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 13 OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 14 To avoid possible fire or shock do not pinch wires between the hanger ball d...

Page 8: ...t before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 15 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 15 3 Using wire connectors supplied...

Page 9: ...until studs protrude through the holes in the ceiling cover Figure 18 8 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 18 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 9 Your ceiling fan in now installed and wired Proceed to Switch Housing Do...

Page 10: ...ousing Downlight Installation SWITCH HOUSING SWITCH HOUSING PLATE SWITCH HOUSING 9 PIN CONNECTOR FAN ASSEMBLY 9 PIN CONNECTOR Figure 21 6 Position the switch housing assembly onto the switch housing plate and secure using the three switch housing screws supplied Figure 22 7 Install three 40 watt max candelabra light bulbs not supplied into the downlight sockets Figure 22 8 Remove the rubber washer...

Page 11: ...Wall Control and Receiver Figure 24 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scre...

Page 12: ...en tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to ra...

Page 13: ... smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories ...

Page 14: ...14 Repair Parts U L Model No CF820 U L Model No CF820 28 29 13 30 15 16 1 7 9 3 2 18 6 35 17 24 23 22 19 20 21 33 34 27 31 29 32 5 8 4 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 10 11 26 14 25 12 ...

Page 15: ...ssembly 1 763536 ORB 763536 PW 24 Glass Assembly Upper 1 763534 763535 25 Flange Assembly 5 per set 763480 ORB 763480 PW 26 Blade Assembly 5 per set 763486 ORB 763486 PW 27 Harness Wiring Reverse Modular Aux Capacitor 1 763528 763528 28 Housing Switch Cup 1 763484 ORB 763484 PW 29 Lower Light Fitter Assembly 1 763531 763531 Washer Rubber 1 Washer Flat 1 Jamnut Hex 1 8 27 NPS 1 30 Glass Lower Shade...

Page 16: ...an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The g...