NON-ADJUSTABLE STEM PACKING SEAL 
INSTALLATION (Standard)

1.   Lubricate stem packing seal with a coating 

of lubricant-silicone grease.

2.   Install stem packing seal (12) on upper 

plug stem and into cap counter bore with 
the "U" shaped side facing valve interior. 
Use the bushing to (4) push the seal into 
the stem bore.

 

NOTE:

 Use thin strapping material inserted in 

between stem diameter and stem seal inside 
diameter to help release air trapped under stem 
seal.

3.   Install retaining ring (11) in stem grove 

to hold bushing (4) in place.

 

NOTE: 

Care should be taken when installing 

retaining ring. Use only properly sized snap ring 
pliers and wear appropriate safety glasses. Take 
care so that the retaining ring does not spring out 
and hit you

.

KEYSTONE

 FIGURE 580 AND 583 BALLCENTRIC VALVES

INSTALLATION AND REPAIR INSTRUCTIONS

ASSEMBLY INSPECTION AND 
TESTING THE VALVE

1.   Rotate plug to ensure proper operation by 

hand, wrench, or operator.

2.   Visually check to ensure full contact of 

plug and seat.

3.   Valve assembly is now ready to be tested.

Rotate the valve to the full close position. 
Apply water pressure to the inlet side of the 
valve and check for leaks at the stem seal 
and plug.

TROUBLESHOOTING

Symptom

Probable cause

Solution

Leakage past the flange face

Flange bolts are not evenly torqued

Loosen the flange bolts and re-tighten the to correct torque per 
ASME requirements. Loosen the flange bolts and re-tighten the to 
correct torque per ASME requirements.

Improper flanges

Confirm mating flange type by referring to AS2129

Leakage in the closed position 
(leakage in the pipeline)

The plug is not closing fully
Actuator is not properly adjusted

Refer to actuator adjustment procedures.

Damage or improperly aligned plug

Follow 'Plug Installation' procedures or replace plug if damaged.

Line pressure exceeds valves working pressure

Reduce line pressure to valve working pressure.

Leakage at the valve stem

Packing (grit excluder) failure

Refer to plug installation

Excessively high torque

Obstruction in the pipeline

Remove valve from pipeline and remove obstruction

Valve stem or plug is bent

Replace plug/stem assembly (check for water hammer or freezing 
of line material)

Scale build-up on stem or seat

Open and close the valve several times. Operate the valve at least 

once a month.

ADJUSTABLE PACKING GLAND AND 
BRIDGE INSTALLATION (Optional)

1.   Place packing gland (16) on upper plug stem 

over stem bushing.

2.   Insert packing bridge studs (15) into body 

cap holes (Note: one end of the studs is 
a left handed thread and one end is right 
handed - the left handed thread should be 
inserted in the cap) and rotate CCW until two 
(2) to three (3) threads have been engaged.

3.   Place packing bridge (17) on upper plug 

stem over packing bridge studs and stem 
packing gland. Place nuts on packing bridge 
studs and tighten by hand. Use appropriate 
tool and adjustment nut to further tighten 
studs until snug.