3. Slide the upper canopy up the rod within 1/4" of the

ceiling or beam and securely tighten the setscrew.

4. If a remote speed control is to be used refer to the

instructions included with that control for proper
installation and wiring.

5. Restore power.

6. After completing installation, test run fan in normal

operation manner. Inspect for any possible shake or
wobble which may be caused by binding as a result of
"tight cable". if this should happen, shut off power supply
and re-check instructions to correct problem.

NOTE: When any solid state motor speed control is
used, a humming noise may be present in the fan on
low speed. This hum in no way affects the operation of
the fan and is acceptable in most industrial
installations.

Maintenance

LUBRICATION - All bearings are permanently lubricated
and do not require further lubrication.

CLEANING - This fan may be wiped off with a damp cloth.
Do not allow the motor to get wet. Do not use solvents or
harsh detergents.

TO AVOID POSSIBLE ELECTRICAL SHOCK, BE SURE
ELECTRICITY IS TURNED OFF AT THE MAIN SERVICE
BOX BEFORE SERVICING.

WARNING

DO NOT USE WATER WHEN CLEARING YOUR CEILING
FAN. IT COULD DAMAGE THE MOTOR OR THE
BLADES AND CREATE THE POSSIBILITY OF AN
ELECTRICAL SHOCK.

WARNING

LIMITED WARRANTY

A

ll products covered by this Owner’s Manual are warranted against defects in workmanship and

materials for one year from date of sale, except for motor which is warranted against defects in
workmanship and materials for two years. This warranty does not apply to damage from accident,
misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate
voltage; nor to equipment improperly installed or wired or maintained in violation of this Owner’s
Manual. This warranty is valid only in the fifty states of the United States. No other written or oral
warranty applies. No employee, agent, dealer or other person is authorized to give any warranties
on behalf of Emerson Electric Co.
The customer shall be responsible for all costs incurred in the removal or reinstallation and
shipping of the product for repairs. Within the limitations of this warranty, inoperative units should
be returned, freight prepaid, to the nearest Emerson authorized service center, or the Emerson
Electric Co. Service Center, and we will repair or replace, at our option, at no charge to you with
return freight paid by Emerson. It is agreed that such repair or replacement is the exclusive
remedy available from Emerson Electric Co. and that EMERSON IS NOT RESPONSIBLE FOR
DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE. Some
states do not allow the exclusion or limitation of incidental or consequential damages, so the
above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
For the address of your nearest authorized service center, call toll-free 1-800-654-3545.
Merchandise returned to the factory must be accompanied by a return authorization and service
identification tag, both available from Air Comfort Products, Division of Emerson Electric Co.,
8100 W. Florissant, St. Louis, MO 63136. When requesting return authorization include all model
numbers shown on the product.

WARNING

THIS PRODUCT IS DESIGNED TO USE ONLY THOSE
PARTS SUPPLIED WITH THIS PRODUCT AND/OR ANY
ACCESSORIES DESIGNATED SPECIFICALLY FOR USE
WITH THIS PRODUCT BY EMERSON ELECTRIC.
SUBSTITUTION OF PARTS OR ACCESSORIES NOT
DESIGNATED FOR USE WITH THIS PRODUCT BY
EMERSON ELECTRIC COULD RESULT IN PERSONAL
INJURY OR PROPERTY DAMAGE.

Before discarding packaging material, be certain all parts have

been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE

FOLLOWING INFORMATION:

PART NUMBER

NAME OF ITEM

PART DESCRIPTION

MODEL NUMBER

The model number of your Fan will be found on a label attached to the

top of the motor.

For repair parts, phone 1-800-654-3545.

Printed in Taiwan   07/98

Part No. F40BP71650001

Form No. BP7165-1

EMERSON

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant, St. Louis, MO 63136

8100 W. Florissant, St. Louis, MO 63136

Key

No.

Description

HF948W 0

1

J-Hook Bag Assembly

761385

J-Hooks (2 ea.)

Hardware (2 ea.)

2

Hanger Assembly

761339

3A

Hanger Nipple, 22”

761387

3B

Hanger Nipple, 8”

761387-2

4

Upper Canopy

761335

5

Lower Canopy

761336

6

Blades (set of 3)

761412

7

Capacitor

761337

Bag Assembly, containing:

761384

8

5/16-18 x 1/4” Setscrews (2 ea.)

9

Hairpin Clip

10

Clevis Pin

11

Safety Wire Clamp (2 ea.)

12

Screw, M6 x 1/2” (6 ea.)

13

Spring Washer, M6 (6 ea.)

14

Blade Gasket (3 ea.)

15

Wire Connector (3 ea.)

16

Allen Wrench

Owner's Manual (Not Shown)

BP7165-1

Summary of Contents for HF948W

Page 1: ...NTALLY WHEN THE SERVICE DISCONNECTING MEANS CANNOT BE LOCKED SECURELY FASTEN A WARNING DEVICE SUCH AS A TAG TO THE SERVICE PANEL 4 SUITABLE FOR USE WITH SOLID STATE SPEED CONTROLS 5 DO NOT BEND THE BLADE BRACKETS WHEN INSTALLING THE BLADES BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS IN BETWEEN THE ROTATING BLADES RULES FOR SAFE INSTALLATION WARNING TO REDUCE THE RISK OF ...

Page 2: ...een the blades and the motor See Figure 3 6 Install the three blades onto the motor using spring washers M6 x 1 2 screws and blade gaskets supplied Securely tighten the six blade screws Hanging Your Heat Fan BLADE BLADE GASKET SPRING WASHER 2 PER BLADE M6 x 1 2 SCREW 2 PER BLADE Figure 3 RUBBER GROMMET CLEVIS PIN HAIRPIN CLIP MOTOR YOKE HANGER PIPE ASSEMBLY MOTOR WIRE 3 SAFETY CABLE 1 MOTOR HAIRPI...

Page 3: ...t end of cable and saddle on long end of cable Improper installation reduces the efficiency of the connection by as much as 40 percent Wiring Your Heat Fan NOTE If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 1 Connect the green grounding wire from the fan motor to the green grounding wire from the supply source Se...

Page 4: ...d freight prepaid to the nearest Emerson authorized service center or the Emerson Electric Co Service Center and we will repair or replace at our option at no charge to you with return freight paid by Emerson It is agreed that such repair or replacement is the exclusive remedy available from Emerson Electric Co and that EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CO...

Reviews: