Emerson Fisher Y696VR Series Instruction Manual Download Page 2

Table 1. 

Body Sizes and End Connection Styles

Installation

!

WARNING

Personal injury, property damage, 

equipment damage, or leakage due to 

escaping gas or bursting of pressure-

containing parts may result if this 

equipment is overpressured or is 

installed where service conditions could 

exceed the limits given in specifications, 

or where conditions exceed any 

ratings of the adjacent piping or piping 

connections. To avoid such injury or 

damage, provide pressure-relieving or 

pressure-limiting devices (as required 

by the appropriate code, regulation, 

or standard) to prevent service 

conditions from exceeding those limits. 

Additionally, physical damage to this 

equipment could cause personal injury 

or property damage due to escaping 

gas. To avoid such injury or damage, 

install the equipment in a safe and well 

ventilated location.

Equipment operation within ratings does not preclude 

the possibility of damage from debris in the lines or from 

external sources. This equipment should be inspected 

for damage after any overpressure condition.

BODY SIZE,  

NPS / DN

CONSTRUCTION MATERIAL AND END CONNECTION STYLE

Cast Iron

Steel or Stainless Steel

Hastelloy

®

 C

1-1/2 / 40

2 / 50

NPT

NPT, SWE, ANSI CL150 RF, 

CL300 RF, or PN 16/25/40

ANSI CL150 RF

  1.  All flanges are welded on to the body and have a face-to-face dimension of 14 in. / 356 mm.

Body Sizes and End Connection Styles

(1)

See Table 1

Maximum Allowable Emergency Inlet  

(Casing) Pressure

(2)

±15 psig / ±1.03 bar

Maximum Allowable Pressure Without Internal  

Parts Damage

(2)

±8 psig / ±0.55 bar

Maximum Downstream Pressure

(2)

Full Vacuum

Vacuum Control Pressure Ranges

(2)

See Table 2

Wide-Open Flow Coefficients

C

g

:

 515

C

v

:

 14.7

C

1

:

 35

IEC Sizing Coefficients

X

T

:

 0.78;

F

D

:

 0.67;

F

L

:

 0.89

  1.  End connections for other than U.S. standards can usually be provided; consult the local Sales Office.

  2.  The pressure/temperature limits in this instruction manual and any applicable standard or code limitation should not be exceeded.

Specifications

Some general ratings and specifications for the Y696VR Series vacuum regulators are given on page 2. Individual 

regulators from the factory are supplied with the specific data stamped on the nameplate.

Spring Case Connection

3/4 NPT

Control Line Connection

1/2 NPT

Gauge Tap Connection

1/4 NPT

Pressure Registration

Type Y696VR:

 Internal

Type Y696VRM:

 External

Material Temperature Capabilities

(2)

Nitrile (NBR):

 -40 to 180°F / -40 to 82°C

Fluorocarbon (FKM):

  40 to 300°F / 4 to 149°C

Ethyleneproplyene (EPR):

 -20 to 275°F /  

-29 to 135°C

Perfluoroelastomer (FFKM):

 0 to 300°F /  

-18 to 149°C

Silicone (VMQ):

 -40 to 400°F / -40 to 204°C

Approximate Weights

Cast Iron:

 45 lbs / 20 kg

Steel, Stainless steel, or Hastelloy

®

 C:

 57 lbs / 

26 kg

Hastelloy

®

 C is a mark owned by Haynes International, Inc.

2

Y696VR Series

Summary of Contents for Fisher Y696VR Series

Page 1: ... may result in equipment damage or personal injury Use qualified personnel when installing operating and maintaining the Y696 Series regulator Introduction Scope of Manual This manual describes and provides instructions and parts lists for the Type Y696VR and the Type Y696VRM vacuum regulators Instructions and parts lists for other equipment used with these breakers are found in separate manuals P...

Page 2: ...he body and have a face to face dimension of 14 in 356 mm Body Sizes and End Connection Styles 1 See Table 1 Maximum Allowable Emergency Inlet Casing Pressure 2 15 psig 1 03 bar Maximum Allowable Pressure Without Internal Parts Damage 2 8 psig 0 55 bar Maximum Downstream Pressure 2 Full Vacuum Vacuum Control Pressure Ranges 2 See Table 2 Wide Open Flow Coefficients Cg 515 Cv 14 7 C1 35 IEC Sizing ...

Page 3: ...d restore the vacuum to its original setting On the Type Y696VR the controlled pressure registers directly into the diaphragm casing The Type Y696VRM has a control line connecting the diaphragm casing to the vacuum being controlled and an O ring stem seal blocking the throat allowing for registration only through the control line connection Startup and Adjustment To place the vacuum regulator in o...

Page 4: ...control spring diaphragm assembly valve stem and stem O ring All pressure must be released from the diaphragm case before these steps can be performed Key numbers are referenced in Figure 3 Type Y696VR Vacuum Regulator 1 Remove the closing cap key 3 and turn the adjusting nut key 2 counterclockwise until all compression is removed from the control spring key 1 If the only further maintenance is to...

Page 5: ...ep 10 2 Remove the spring case cap screws key 21 and hex nuts key 22 and remove the spring case key 23 3 Remove the diaphragm key 5 and attached parts by tilting it so the pusher post key 8 slips off the lever assembly key 9 To separate the diaphragm key 5 from the attached parts unscrew the diaphragm hex nut key 37 If the only further maintenance is to replace the diaphragm parts or change the co...

Page 6: ...1A309324122 NACE 1A309338992 Recommended Spare Parts Hastelloy C is a mark owned by Haynes International Inc 4 To replace the lever assembly key 9 remove the machine screws key 11 and lever pin 5 To replace the valve stem key 13 or stem seal O ring key 15 remove the valve stem from the diaphragm casing 6 Lightly grease the new stem seal O ring key 15 and install on the valve stem key 13 Install th...

Page 7: ...em Stainless steel standard 0L025135032 Stainless steel NACE 0L0251X0022 Hastelloy C 0L0251X0012 41 Valve Spring 303 Stainless Steel standard 0D002827022 316 Stainless Steel NACE or Hastelloy C 10B6027X012 44 Upper Spring Seat 1 to 3 in w c 2 to 7 mbar 1A869524092 1 1 2 to 5 in w c 4 to 12 mbar 1A869524092 3 to 8 in w c 7 to 20 mbar 1A869524092 8 to 16 in w c 20 to 40 mbar 1A869524092 16 to 32 in ...

Page 8: ...ify or improve the designs or specifications of our products at any time without notice Emerson Process Management Regulator Technologies Inc does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser A7176 TYPE Y696V...

Reviews: