Emerson FISHER T208 Series Installation Manual Download Page 2

2

T208 Series

Clean out all pipelines before installation of the 

regulator and check to be sure the regulator has 

not been damaged or has collected foreign material 

during shipping.  For NPT bodies, apply pipe 

compound to the external pipe threads.  For flanged 

bodies, use suitable line gaskets and approved 

piping and bolting practices.  Install the regulator in 

any position desired

(1)

, unless otherwise specified, 

but be sure flow through the body is in the direction 

indicated by the arrow on the body.

Note

It is important that the regulator be 

installed so that the vent hole in the 

spring case is unobstructed at all 

times.  For outdoor installations, the 

regulator should be located away from 

vehicular traffic and positioned so that 

water, ice, and other foreign materials 

cannot enter the spring case through 

the vent.  Avoid placing the regulator 

beneath eaves or downspouts, and 

be sure it is above the probable 

snow level. 

Overpressure Protection

Recommended pressure limitations are stamped 

on the regulator nameplate.  Vapor recovery 

regulators are used to maintain a constant inlet 

(blanket) pressure with the outlet flowing to a system 

whose pressure is lower than that at the inlet.  

The recovery regulators are not intended to be used 

as an ASME certified relief device for overpressure 

protection on a tank.  They are to be used as part 

of a gas blanketing system to control outflow of 

blanketing gas under normal conditions and collect 

tank vapors for the vapor disposal reclamation 

system.  Provide alternate methods of emergency 

overpressure protection.

Startup

The regulator is factory set at approximately 

the midpoint of the spring range or the pressure 

requested, so an initial adjustment may be required 

to give the desired results.  With proper installation 

completed and relief valves properly adjusted, slowly 

open the upstream and downstream shutoff valves.

Adjustment

To change the control pressure, perform the 

following procedure.

For internal flat circular adjusting screw:

1. 

Remove the closing cap (key 22).

2. 

Use a 25 mm / 1-inch hex rod or flat screwdriver 

to turn the adjusting screw (key 35) either 

clockwise to increase control pressure or 

counterclockwise to decrease control pressure.  

The regulator will go into immediate operation.  

To ensure correct operation, always use a 

pressure gauge to monitor the vapor recovery 

pressure when making adjustments.

3.  After making the adjustment, replace the closing 

cap gasket (key 25) and install the closing cap 

(key 22).

For external square head adjusting screw:

1. 

Loosen the locknut (key 20).

2. 

Turn the adjusting screw (key 35) either 

clockwise to increase control pressure or 

counterclockwise to decrease control pressure.  

Always use pressure gauge to monitor the vapor 

recovery pressure when making adjustments.

3.  After making the adjustment, tighten the locknut 

(key 20).

Taking Out of Service (Shutdown)

!

WARNING

To avoid personal injury resulting from 

sudden release of pressure, isolate the 

regulator from all pressure before 

attempting disassembly.

Parts List

Key   Description 

 1 

Body

  2  

Cap Screw (2 required)

  3  

Spring Case

  4 

Lower Casing

  5*   Orifice

  6  

Spring

  7  

Diaphragm Head  

 

  (2 required)

  8  

Pusher Post

  9  

Diaphragm Gasket

  10*   Diaphragm

  11*   Body Seal O-ring

  12*   Insert Seal O-ring

  13*   Disk Assembly

  14   Stem

  16   Lever Assembly

  17   Machine Screw 

 

 

  (2 required)

  18   Guide Insert

  19  Upper spring seat

(2)

  20  Lock Nut

(2)

  22   Closing Cap

  23   Hex Nut (8 required)

  24   Cap Screw (8 required)

  25*   Closing Cap Gasket

Key   Description

  26   Vent Assembly

  27   Pipe Plug 

 

 

  (Type T208 only) 

 

  30*   Stem Seal O-ring  

 

  (Type T208M only)

  31*  Throat Seal O-ring  

 

  (Type T208M only)

  34   Machine Screw 

 

 

  (Type T208M only)

  35   Adjusting Screw

  36   Washer

  38   Cap Screw

  41   Back Disk Spring

  42*   Back Body Seal O-ring

  43   Back Body Cap

  44   Disk Spacer 

  45*  Diaphragm Head Gasket

  46   Nameplate

  47   Drive screw (2 required)

  48   Flow arrow

  49   Backup Ring

  50   Lower Spring Seat

  51  NACE Tag (not shown)

  52   Tag Wire (not shown)

*Recommended Spare Part

1.  For proper operation to achieve the published capacities at low setpoint, the spring case barrel should be installed pointed down as shown in Figure 1. 

2.   Use for optional external square head adjusting screw assembly recommended for 62 to 172 mbar / 0.9 to 2.5 psig, 90 to 310 mbar / 1.3 to 4.5 psig, and 0.26 to 0.48 bar / 

 

3.8 to 7 psig spring ranges only.

Summary of Contents for FISHER T208 Series

Page 1: ... VI Soft Seat Pressure Registration Type T208 Internal Type T208M External 1 The pressure temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded 2 See Table 3 for operating temperature ranges for available trim combinations Material Temperature Capabilities 1 2 Nitrile NBR 29 to 82 C 20 to 180 F Fluorinated Ethylene Propylene FEP 29 to 8...

Page 2: ...e a 25 mm 1 inch hex rod or flat screwdriver to turn the adjusting screw key 35 either clockwise to increase control pressure or counterclockwise to decrease control pressure The regulator will go into immediate operation To ensure correct operation always use a pressure gauge to monitor the vapor recovery pressure when making adjustments 3 After making the adjustment replace the closing cap gaske...

Page 3: ...o 0 48 bar 3 8 to 7 psig spring ranges only ERSA02737 ERSA02738 ERSA02737 10 7 45 8 16 12 11 49 42 17 44 L1 L2 L2 L1 L1 9 7 50 36 6 35 14 18 13 41 5 38 10 7 45 8 16 12 30 11 49 42 17 44 9 7 50 36 6 35 14 18 31 34 41 5 38 L1 L1 L1 L1 L1 L2 L2 20 19 35 22 6 L2 TYPE T208 ASSEMBLY WITH INTERNAL PRESSURE REGISTRATION TYPE T208M ASSEMBLY WITH EXTERNAL PRESSURE REGISTRATION EXTERNAL SQUARE HEAD ADJUSTING...

Page 4: ...892 9499 For further information visit www fisherregulators com The distinctive diamond shape cast into every spring case uniquely identifies the regulator as part of the Fisher brand and assures you of the highest quality engineering durability performance and support Table 2 Control Pressure Ranges and Spring Information CONTROL PRESSURE RANGE SPRING PART NUMBER SPRING COLOR SPRING WIRE DIAMETER...

Reviews: