background image

D103578XUS2 

Installation Guide

English – November 2014

Type LR128

www.fisherregulators.com

Introduction

This installation guide provides instructions for 

installation, startup and adjustment. To receive a copy 

of the instruction manual, contact your local Sales 

Office or view a copy at www.fisherregulators.com. For 

further information refer to: Type LR128 Instruction 

Manual, D103578X012.

P.E.D. Categories

This product may be used as a pressure accessory 

with pressure equipment in the following Pressure 

Equipment Directive 97/23/EC categories.

PRODUCT SIZE

CATEGORY

FLUID TYPE

DN 25 and 50 / 1 and 2 in.

SEP

Liquid

DN 80 and 100 / 3 and 4 in.

II

Liquid

Specifications

Main Valve Body Sizes, End Connection Styles 

and Body Ratings

(1)

See Table 1

Maximum Control Pressure

(1)

See Tables 1, 2 and 5

Minimum Set Pressure

(1)

1.7 bar / 25 psig

Set Pressure or Backpressure Control Ranges

(1)

See Table 4

Temperature Capabilities

(1)

See Table 3 

Installation

!

WARnInG

Only qualified personnel shall install or 

service a relief valve or backpressure 

regulator. Relief valve or backpressure 

regulator should be installed, operated 

and maintained in accordance with 

international and applicable codes 

and regulations and Emerson Process 

Management Regulator Technologies, 

Inc. (Emerson™) instructions.
If using a relief valve or backpressure 

regulator on a hazardous or flammable 

fluid service, personal injury and 

property damage could occur due to 

fire or explosion of vented fluid that 

may have accumulated. To prevent 

1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.

such injury or damage, provide piping 

or tubing to vent the fluid to a safe, 

well-ventilated area or containment 

vessel. Also, when venting a hazardous 

fluid, the piping or tubing should be 

located far enough away from any 

buildings or windows so to not create 

a further hazard and the vent opening 

should be protected against anything 

that could clog it.
Personal injury, equipment damage 

or leakage due to escaping fluid 

or bursting of pressure-containing 

parts may result if this relief valve 

or backpressure regulator is 

overpressured or is installed where 

service conditions could exceed the 

limits given in the Specifications 

section or where conditions exceed 

any ratings of the adjacent piping or 

piping connections.

To avoid such injury or damage, 

provide pressure-relieving or pressure-

limiting devices (as required by 

the appropriate code, regulation or 

standard) to prevent service conditions 

from exceeding limits.

Additionally, physical damage to the 

relief valve or backpressure regulator 

could result in personal injury and 

property damage due to escaping fluid. 

To avoid such injury and damage, 

install the relief valve or backpressure 

regulator in a safe location.

Clean out all pipelines before installation of the 

relief valve or backpressure regulator and check to 

be sure the relief valve or backpressure regulator 

has not been damaged or has collected foreign 

material during shipping. For NPT bodies, apply pipe 

compound to the external pipe threads. For flanged 

bodies, use suitable line gaskets and approved 

piping and bolting practices. Install the relief valve 

or backpressure regulator in any position desired, 

unless otherwise specified, but be sure flow through 

the body is in the direction indicated by the arrow 

 

on the body. 

Summary of Contents for FISHER LR128 Series

Page 1: ...code limitation should not be exceeded such injury or damage provide piping or tubing to vent the fluid to a safe well ventilated area or containment vessel Also when venting a hazardous fluid the piping or tubing should be located far enough away from any buildings or windows so to not create a further hazard and the vent opening should be protected against anything that could clog it Personal in...

Page 2: ... 0 450 31 0 450 CL150 RF 19 0 275 19 0 275 19 0 275 CL300 RF 49 6 720 31 0 450 31 0 450 CL600 RF 99 2 1440 PN 16 25 40 RF 40 0 580 1 The pressure temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded 2 Ratings and end connections for other than ASME standard can usually be provided Contact your local Sales Office for assistance 3 Maximu...

Page 3: ... Cap Screw 17 Jam Nut 28 Lock Washer 29 Gasket 31 Locknut 58 Washer 63 Bottom Seal Plug DN 25 1 in BODY SIZE DN 50 80 and 100 2 3 and 4 in BODY SIZES APPLY Lubricant SEALANt 1 L1 Lithium Polymer Type Lubricant Multi purpose Grease L2 Anti seize lubricant s medium strength threadlocker APPLY Lubricant SEALANT 1 L1 General Purpose PTFE or Lithium Grease for O rings L2 Anti Seize Compound L4 Graphite...

Page 4: ...ING FREE LENGTH SPRING PART NUMBER AND COLOR bar psig mm In mm In Type MR98H 1 7 to 5 2 4 8 to 9 7 9 0 to 13 8 10 3 to 25 9 1 25 to 75 70 to 140 130 to 200 150 to 375 1 5 94 7 19 8 41 10 0 0 234 0 283 0 331 0 394 65 9 62 0 57 2 129 2 595 2 44 2 250 5 063 ERAA01910A0 Green ERAA01911A0 Red ERAA02889A0 Blue 1N943427142 Unpainted 1 150 to 375 psig 10 3 to 25 9 bar spring range is for the Type MR98HH p...

Reviews: