DVC6000 Digital Valve Controllers
ii
Fast Key Sequence for Instrument Level HC, AD, PD, and ODV
Function/Variable
Fast-Key
Sequence
Coordinates
Function/Variable
Fast-Key
Sequence
Coordinates
(1)
Partial Stroke Test
2-5
2-F
Travel
3-3
2-G
Partial Stroke Test Enable
1-2-7-1
3-D
1-2-3-4-1
9-E
Partial Stroke Test Pressure Limit
1-2-3-6-1
10-G
Travel / Pressure Select
1-2-2-2-1
6-C
Partial Stroke Test Start Point
1-2-2-2-4-2
8-D
Travel Accumulatorv
3-6-6
4-H
Partial Stroke Test Variables
View/Edit
1-2-7-2
3-D
1-2-3-5-3-2
12-H
Performance Tuner
1-1-2
2-B
Travel Accumulator Alert Enable
1-2-3-5-3-1
12-H
1-2-2-1-1-5
8-A
Travel Accumulator Alert Point
1-2-3-5-3-3
12-I
Polling Address
1-2-5-1-7
6-G
Travel Alert Dead Band
1-2-3-4-3
9-E
Pressure A
3-5-1
4-G
Travel Alert Hi Enable
1-2-3-4-6-1
10-F
Pressure B
3-5-2
4-G
Travel Alert Hi Hi Enable
1-2-3-4-5-1
12-E
Pressure Control Active Enable
1-2-4-3-1
8-H
Travel Alert Hi Hi Point
1-2-3-4-5-3
12-F
Pressure Deviation Alert Enable
1-2-3-6-2
10-G
Travel Alert Hi Point
1-2-3-4-6-3
10-F
Pressure Deviation Alert Point
1-2-3-6-3
10-G
Travel Alert Lo Enable
1-2-3-4-6-2
10-F
Pressure Deviation Time
1-2-3-6-4
10-G
Travel Alert Lo Lo Enable
1-2-3-4-5-2
12-E
Pressure Range Hi
1-2-2-2-3-1
10-D
Travel Alert Lo Lo Point
1-2-3-4-5-4
12-F
Pressure Range Lo
1-2-2-2-3-2
10-D
Travel Alert Lo Point
1-2-3-4-6-4
10-F
Pressure Sensor Shutdown
1-2-3-2-3
12-D
Travel Deviation Alert Enable
1-2-3-4-4-1
10-E
Pressure Sensors—Calibration
1-3-2-1
4-E
Travel Deviation Alert Point
1-2-3-4-4-2
10-E
Pressure Tuning Set
1-2-2-1-3-1
8-B
Travel Deviation Time
1-2-3-4-4-3
10-E
Pressure Units
1-2-5-2-1
6-G
Travel Limit / Cutoff Hi Enable
1-2-3-4-7-1
12-F
Protection
Hot Key-3
1-A
Travel Limit / Cutoff Lo Enable
1-2-3-4-7-2
12-F
1-2-1-5
4-B
Travel Limit Hi
1-2-3-4-7-6
12-G
Raw Travel Input
3-6-7
4-H
1-2-2-2-2-4
10-C
Reference Voltage Shutdown
1-2-3-1-3-7
12-C
Travel Limit Lo
1-2-3-4-7-7
12-G
Relay Adjust
1-3-3
3-E
1-2-2-2-2-5
10-C
Relay Type
1-2-5-4
4-F
Travel Sensor Adjust
1
−
3
−
2
−
2
4
−
E
Restart Control Mode
1-2-1-3
4-B
Travel Sensor Motion
1-2-6-5
3-E
Restore Factory Settings
1-3-4
3-E
Travel Sensor Shutdown
1-2-3-2-1
12-C
Set Point Rate Close
1-2-2-5-2
5-D
Travel Setpoint
1-2-3-4-2
9-E
Set Point Rate Open
1-2-2-5-1
5-D
3-2
2-G
Setup Wizard
1-1-1
2-B
Travel Tuning Set
1-2-2-1-1-1
8-A
Stabilize/Optimize
Hot Key-4
1-A
Valve Group Enable
1-2-3-6-5-2
10-H
1-1-2
2-B
1-2-3-7-5-2
1-2-2-1-1-4
8-A
Valve Serial Number
1-2-5-1-5
6-F
Status
2-2
2-F
1-2-6-2
3-D
Stroke Valve
2-4
2-F
Valve Style
1-2-6-3
3-D
Supply Pressure
3-5-4
4-G
View Alert Records
1-2-3-6-3
10-H
1-2-3-3-2-2
12-E
1-2-3-7-3
Supply Pressure Lo Alert Enable
1-2-3-3-2-1
12-E
View/Edit Feedback Connection
1-2-6-6
3-E
Supply Pressure Lo Alert Point
1-2-3-3-2-3
12-E
View/Edit Lag Time
1-2-2-5-3
5-D
Temperature
3-6-2
4-H
View/Edit Lead/Lag
1-2-2-5-3
5-D
Temperature Sensor Shutdown
1-2-3-2-2
12-D
View Number of Days Powered Up
2-3-3
3-F
Temperature Units
1-2-5-2-2
6-G
3-6-8
4-H
Zero Power Condition
1-2-5-5
4-G
NOTE: Italicized Fast-Key Sequence indicates fast-key sequence is applicable only for instrument level ODV.
1. Coordinates are to help locate the item on the menu tree on the following pages.
2. Not available in instrument level HC.
3. Instrument level ODV only.
4. Instrument level HC only.
5. Instrument level HC, AD, and PD only.
6
7. Firmware 7 only.
Summary of Contents for Fisher FIELDVUE DVC6000
Page 2: ......
Page 22: ...DVC6000 Digital Valve Controllers September 2013 1 12 1 ...
Page 82: ...DVC6000 Digital Valve Controllers September 2013 4 22 4 ...
Page 94: ...DVC6000 Digital Valve Controllers September 2013 5 12 5 ...
Page 139: ...Loop Schematics Nameplates September 2013 B 1 B B Appendix B Loop Schematics Nameplates B ...
Page 161: ......