background image

Instruction Manual

D103373X012

87000 Valve

November 2011

2

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and

warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office

before proceeding.

WARNING

Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal

injury.
Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result

if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief valve for

over pressure protection as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process

media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this

instruction manual.

CAUTION

This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying

different pressures and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of

control of the process. Do not expose this product to service conditions or variables other than those for which the product

was intended. If you are not sure what these conditions are you should contact your Emerson Process Management sales

office for more complete specifications. Provide the product serial numbers (shown on the nameplate) and all other

pertinent information.

WARNING

If you move or work on an actuator installed on a valve with loading pressure applied, keep your hands and tools away

from the stem travel path to avoid personal injury. Be especially careful when removing the stem connector to release all

loading on the actuator stem whether it be from air pressure on the diaphragm or compression in the actuator springs.
Likewise take similar care when adjusting or removing any optional travel stop. Refer to the relevant actuator Maintenance

Instructions.

Maintenance

WARNING

Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before

performing any maintenance operations:

D

Do not remove the actuator from the valve while the valve is still pressurized.

D

Always wear protective gloves, clothing, and eyewear when performing any maintenance operations.

D

Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the

actuator cannot suddenly open or close the valve.

Summary of Contents for Fisher Baumann 87000

Page 1: ...eous media The valve is suitable for repeated steam sterilization cycles with 35 psi maximum steam pressures Assembly of valve body sections uses only two bolts allowing for ease of cleaning and inspection A lower telltale port is provided The valve will drain either horizontally or vertically with the actuator in the horizontal position The operation is not affected by vacuum Scope of Manual This...

Page 2: ... parts damage malfunction of the control valve or loss of control of the process Do not expose this product to service conditions or variables other than those for which the product was intended If you are not sure what these conditions are you should contact your Emerson Process Management sales office for more complete specifications Provide the product serial numbers shown on the nameplate and ...

Page 3: ...use the used gasket may not seal properly WARNING Avoid personal injury or property damage by thoroughly cleaning the line of all dirt welding chips scale oil or grease and other foreign material Failure to do so could result in damage to the seating and sealing surfaces of the valve and result in release of process materials Installation and Maintenance 1 Before installing the valve in the pipeli...

Page 4: ...s not fall out of the assembly and get lost 4 In order to remove the shaft key 4 unscrew the alignment pin key 15 and remove the retaining ring key 11 Reassembly of Valve Refer to figures 3 4 and 5 1 Reassemble the valve in reverse order using the instructions above The valve body is designed so it cannot be assembled improperly Make sure the beveled edge of the anvil key 8 points toward the ceram...

Page 5: ...e following parts tables WARNING Use only genuine Fisherr replacement parts Components that are not supplied by Emerson Process Management should not under any circumstances be used in any Fisher valve because they may void your warranty might adversely affect the performance of the valve and could cause personal injury and property damage Figure 2 Baumann 87000 Valve E1369 E1234 AIR TO EXTEND AIR...

Page 6: ...1 Bonnet Upper 87305 3 1 Bonnet Lower 87306 4 1 Shaft 87505 5 1 Ceramic Ball 87405 6 1 Sleeve Bushing 87605 7 1 Sleeve VMQ Silicone 87705 688 Sleeve EPDM 87705 709 Sleeve FKM Fluorocarbon 87705 697 Sleeve FFKM Perfluoroelastomer Consult Factory 87705 703 8 1 Anvil 87406 9 2 O Ring VMQ Silicone 87706 688 O Ring EPDM 87706 709 O Ring FKM Fluorocarbon 87706 697 O Ring FFKM Perfluoroelastomer Consult ...

Page 7: ...296 Mode of Operation As shown in figure 6 a flexible sleeve is inserted through the length of the valve and sealed between the valve body and bonnet by O rings The actuator motivated valve stem has a tapered groove that pushes a ceramic ball against the inside of the sleeve and thereby the sleeve against a valve seat Figure 7 Sleeve Clearance E1374 ...

Page 8: ...sions E1297 159 46 25 38 1 5 RECOMMENDED MOUNTING FOR SELF DRAINING ACTUATOR SHOULD BE MOUNTED HORIZONTALLY NOTE ACTUATOR REQUIRES 115 mm 4 5 INCHES VERTICAL CLEARANCE 21 0 83 9 0 34 70 2 75 SELF DRAIN ANGLE 2 DEGREES 26 1 03 146 5 8 27 1 05 21 0 83 9 0 34 FLOW FLOW mm inch ...

Page 9: ...373X012 87000 Valve November 2011 9 Figure 9 Dimensions E1299 166 6 52 127 5 0 mm inch RECOMMENDED MOUNTING FOR SELF DRAINING ACTUATOR SHOULD BE MOUNTED HORIZONTALLY NOTE ACTUATOR REQUIRES 115 mm 4 5 INCHES VERTICAL CLEARANCE ...

Page 10: ...E ACTUATOR REQUIRES 115mm 4 5 INCHES VERTICAL CLEARANCE 250 9 8 26 1 03 146 5 8 R228 R9 0 6 40 25 205 48 06 mm inch Table 2 Weights Valve Actuator and Positioner VALVE ACTUATOR POSITIONER 1 Size Travel Weight Baumann 16 FIELDVUE DVC2000 FIELDVUE DVC6010 DN NPS mm Inch kg lb kg lb kg lb kg lb 15 1 2 7 9 0 3125 3 6 8 4 5 10 1 5 3 3 3 5 7 7 1 Not available with Fisher 3660 3661 positioner ...

Page 11: ...Instruction Manual D103373X012 87000 Valve November 2011 11 ...

Page 12: ...available upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice EFisher Controls International LLC 2009 2011 All Rights Reserved Baumann Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co Emerson Process Management Emerson and the Emerson lo...

Reviews: