Table 3. Fisher 3570 Actuator Specifications

Available Configurations

3570: Valve positioner with two relays and three

pressure gauges for monitoring input signal and

output pressures to the top and underside of the

actuator piston

3570C: Similar to 3570 except that the positioner is

equipped with automotive tire valves instead of

pressure gauges. The valves can be used for clip-on

test pressures gauges. The relay nozzles on these

positioners are locked in place with locknuts to resist

unwanted nozzle movement due to vibration

Input Signal

Standard Ranges: 0.2 to 1.0 bar (3 to 15 psig) or 0.4

to 2.0 bar (6 to 30 psig)

Split Ranges: Typically uses one half of standard range

when two control valves are operated by one input

signal from a single controller

Optional Ranges: As required within the limits of the

bellows

Bellows Pressure Rating

Standard Bellows: 3.4 bar (50 psig)

Optional Bellows: 6.2 bar (90 psig)

Supply Pressure

Maximum: 10.3 bar (150 psig)

Minimum: 2.4 bar (35 psig)

Output Signal

Type: Pneumatic pressure as required by the actuator

Action: Field reversible between direct and reverse

(see table 4)

Hysteresis

(1,2)

0.15% of total stroke or instrument pressure span

Resolution

(1,2)

0.2% of instrument pressure span

Repeatability

(1,2)

0.3% of instrument pressure span

Frequency Response

(1,2)

See figure 3

Pressure Connections

Vent: 3/8 NPT

All Others: 1/4 NPT

Pressure Indications

3570C: Tire valves accept standard pressure gauge

chucks

3570: See table below

Type of Indication

Number

Used

Standard Gauge Range

bar (psig)

Positioner input signal

gauge

1

0 to 2.1 (0 to 30) or

0 to 4.1 (0 to 60)

Cylinder supply pressure

gauge

0

0 to 11.0 (0 to 160)

Static Air Consumption

(3)

0.56 normal m

3

/hr (20 scfh) with 6.9 bar

(100 psig) supply pressure

Operative Ambient Temperature

(1,2)

With Nitrile O-Rings: -34 to 79

_

C (-30 to 175

_

F)

With Fluorocarbon O-Rings (Optional):

(3)

-18 to 149

_

C (0 to 300

_

F)

Construction Materials

Actuator:

Part

Material

Base, Cover and Beam

Bellows

Bias and Range Spring

Relay Body

Relay Nozzle(s)

Diaphragm

O-Rings

Aluminum, die cast

Brass

Steel, Plated

Zinc, Die Cast

SST

Nitrile or Fluorocarbon
Nitrile or Fluorocarbon

Options

Fisher SS-52 clip-on chuck (with or without gauge) for

3570C positioners

1. These terms are defined in ANSI/ISA Standard S51.1

2. For actuator with positioner only. Does not apply to other constructions or actuator-valve combination.

3. Normal m

3

/hr.- normal cubic meters per hour (0

_

C and 1.01325 bar, absolute); Scfh - standard cubic feet per hour (60

_

F and 14.7 psia).

Summary of Contents for Fisher 480 Series

Page 1: ...llation operation and maintenance To avoid personal injury or property damage it is important to carefully read understand and follow all the contents of this manual including all safety cautions and warnings If you have any questions about these instructions contact your Emerson Process Management sales office before proceeding Description 480 Series actuators figure 1 are yokeless piston actuato...

Page 2: ... Material Cylinder and Piston Aluminum Piston Rod Extension SST Chrome Plated Cylinder Seal Bushings Brass O Rings Nitrile or Fluorocarbon Options J 376 Series trip valve system to fail actuator J up or J down or J lock in last position J TopWorxt DXP M21GNEB electrical valve stem position switch J Micro Switch limit switches 1 Normal m3 hr normal cubic meters per hour 0_C and 1 01325 bar absolute...

Page 3: ... 4 Hysteresis 1 2 0 15 of total stroke or instrument pressure span Resolution 1 2 0 2 of instrument pressure span Repeatability 1 2 0 3 of instrument pressure span Frequency Response 1 2 See figure 3 Pressure Connections Vent 3 8 NPT All Others 1 4 NPT Pressure Indications 3570C Tire valves accept standard pressure gauge chucks 3570 See table below Type of Indication Number Used Standard Gauge Ran...

Page 4: ...piston actuator with positioner 481 Yokeless piston actuator without positioner Other actuators may be obtained without positioner by adding 1 to the type number The above actuators come with standard mounting flange 105 mm 4 125 inch maximum rated travel and threaded piston rod connection with sizes 30 through 60 for mounting on ball valves louvers and dampers with brackets These actuators may be...

Page 5: ...for overpressure protection as required by accepted industry or local state and Federal codes and good engineering practices Check with your process or safety engineer for any additional measures that must be taken to protect against process media If installing into an existing application also refer to the WARNING at the beginning of the Maintenance section in this instruction manual Inspect this...

Page 6: ...Location All Actuators ACTUATOR SIZE C H DEGREE OF ARC mm Inch Standard Flange Universal Mounting Flange 30 171 6 75 0 45 40 206 8 12 45 45 60 267 10 50 22 5 45 Figure 6 Operation of Actuator with Snubber 32A8303 A A1287 SNUBBER POSITIONER OR SWITCH ING DEVICE SUPPLY PRESSURE TOP CYLINDER PRESSURE BOTTOM CYLINDER PRESSURE UPPER SNUBBER PRESSURE LOWER SNUBBER PRESSURE CHECK VALVES Principle of Oper...

Page 7: ...ures a definite position of the piston and valve plug for a given instrument signal If upward piston motion is required the beam pivots over the nozzle on relay B The result is relay piston and feedback action opposite that for downward piston motion Reversal of positioner action is accomplished simply by removing four screws inverting the bellows and installing two bellows posts for support it th...

Page 8: ...onnect any operating lines providing air pressure or a control signal to the actuator Be sure the actuator cannot suddenly open or close the valve D Use bypass valves or completely shut off the process to isolate the valve from process pressure Relieve process pressure on both sides of the valve Drain the process media from both sides of the valve D Use lock out procedures to be sure that the abov...

Page 9: ...vis and the boot locknut from the actuator piston rod 7 Remove the nuts that hold the cylinder to the mounting flange and lift off the cylinder 8 Remove the stud bolts key 123 that hold the cylinder to the cylinder flange Two slots 180 degrees apart are located at the lower edge of the cylinder Insert a screwdriver in these slots and pry the cylinder loose The piston and piston rod will come out w...

Page 10: ...Instruction Manual D100291X012 480 Series Actuators August 2012 10 Figure 7 Fisher 480 Piston Actuator Size 30 60 40A9540 A PARTS NOT SHOWN 27 AND 112 ...

Page 11: ...Instruction Manual D100291X012 480 Series Actuators August 2012 11 Figure 8 Fisher 481 Piston Actuator Size 30 60 40A9538 A PARTS NOT SHOWN 27 78 79 AND 112 ...

Page 12: ...rew 24 Piston Rod Boot Sizes 30 40 and 60 1H93790699 25 Top Boot Snap Ring 26 Bottom Boot Snap Ring 27 Travel stop 30 Piston Nut 31 Positioner 45 Spring Retainer Spacer 78 Cover Seal 481 only 1C85380699 79 Cover Screw 160 Pipe Plug Recommended spare parts Emerson Process Management Marshalltown Iowa 50158 USA Sorocaba 18087 Brazil Chatham Kent ME4 4QZ UK Dubai United Arab Emirates Singapore 128461...

Reviews: