background image

Type 122A 

D100263X012

January 2016

Instruction Manual

Form 2279

www.fisherregulators.com

Type 122A Three-Way Switching Valve

!

WARNING

Failure to follow these instructions or 

to properly install and maintain this 

equipment could result in an explosion, 

fire and/or chemical contamination 

causing property damage and personal 

injury or death.
Fisher

®

 switching valves must be 

installed, operated and maintained 

in accordance with federal, 

state and local codes, rules and 

regulations and Emerson Process 

Management Regulator Technologies, 

Inc. instructions.
If the switching valve vents gas or a 

leak develops in the system, service 

to the unit may be required. Failure 

to correct trouble could result in a 

hazardous condition. 
Installation, operation and maintenance 

procedures performed by unqualified 

personnel may result in improper 

adjustment and unsafe operation. Either 

condition may result in equipment 

damage or personal injury. Only 

qualified personnel shall install, operate 

and maintain the Type 122A three-way 

switching valve. 

Introduction

Scope of the Manual

This Instruction Manual includes installation, 

adjustment, maintenance and parts ordering 

information for the Type 122A three-way 

switching valve.

Description

The Type 122A three-way switching valve (see 

Figure 1) is a high-capacity, economical three-way 

pneumatic switching valve for on-off applications. This 

valve can be used for diverging or converging gaseous 

service, diverging liquid service with gas-loaded liquids 

and converging liquid service. Six spring ranges are 

available for control pressures from 3 to 150 psig / 

0.21 to 10.3 bar.

Figure 1.

 Type 122A Three-Way Switching Valve

W3141-1

Summary of Contents for Fisher 122A Series

Page 1: ...lation operation and maintenance procedures performed by unqualified personnel may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Only qualified personnel shall install operate and maintain the Type 122A three way switching valve Introduction Scope of the Manual This Instruction Manual includes installation adjustment maintenan...

Page 2: ...ients Cg 2 Connection A to B 138 Connection A to C 131 C1 Connection A to B 28 0 Connection A to C 32 5 Control Connection 1 4 NPT Approximate Weight 5 lbs 2 3 kg 1 The pressure temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded 2 At an inlet pressure of 25 psig 1 7 bar and with full pressure drop across the body Principle of Operati...

Page 3: ...ematic INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE A2606 INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE ADJUSTING SCREW UPPER VALVE SEAT LOWER VALVE SEAT DIAPHRAGM SPRING STEM PORT D PORT A PORT C PORT B VALVE ...

Page 4: ...h proper installation completed and downstream equipment properly adjusted slowly open the upstream and downstream shutoff valve when used while using pressure gauges to monitor pressure WARNING To avoid personal injury property damage or equipment damage caused by bursting of pressure containing parts or explosion of accumulated gas never adjust the control spring to produce an outlet pressure hi...

Page 5: ...e upper seat ring key 24 Assembly 1 Screw the upper seat ring key 24 into the body key 23 2 Install the back up rings and O rings keys 13 and 12 into each end of the diaphragm case key 2 3 Install the washer key 17 and three felt washers key 18 into the valve end of the diaphragm case Replace the guide bushings key 15 in each end of the diaphragm casing Carefully insert the stem key 5 through the ...

Page 6: ...022 18 Washer Neoprene CR Felt 3 required 1K787206992 19 Union Nut Ductile iron 1E471119062 Recommended spare parts 20 Snap Ring Plated steel 1A832648722 21 Body Gasket Composition 1A832504032 22 Disk Holder Assembly Aluminum Nitrile NBR 1R1772000A2 Stainless steel Nitrile NBR 1R1772X00A2 Stainless steel Fluorocarbon FKM 1R1772X0032 23 Body Cast iron 3 4 NPT 1D3124X0022 1 NPT 1D3125X0022 WCC Steel...

Page 7: ...Type 122A 7 Figure 3 Type 122A Three Way Switching Valve Assembly 20A9801 A 7 1 3 5 29 9 12 10 13 15 2 19 C A B 24 37 36 23 22 18 21 17 13 12 14 16 4 26 8 6 4 25 28 31 30 20 ...

Page 8: ...ntenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Africa...