1-15-3
E9400PIN
20
IN
XCIN
Sub Clock Input
21
OUT XCOUT
Sub Clock Output
22
IN
XIN
Main Clock Input
23
OUT XOUT
Main Clock Output
24
-
GND
Ground
25
OUT PWSW
Main Power Control Signal
26
-
N.U.
Not Used
27
-
N.U.
Not Used
28
-
N.U.
Not Used
29
OUT S-CS
Communication of Select
with VCR Micro Controller
30
IN
S-DATA-
OUT
Communication of Data
from VCR Micro Controller
31
OUT S-DATA-IN
Communication of Data to
VCR Micro Controller
32
OUT S-CLK
Communication of Clock
with VCR Micro Controller
33
OUT VCR/TV
RF Conv. ON/OFF Signal
(TV="L"/VIDEO="H")
34
OUT CONV-SW
RF Conv. Output Channel
Switching Signal 3ch=”Hi-
z”, 4ch=”L”
35
-
N.U.
Not Used
36
-
N.U.
Not Used
37
-
N.U.
Not Used
38
-
N.U.
Not Used
39
OUT V-MUTE
Video Mute Control Signal
40
OUT
SYS-
RESET
System Reset Signal
41
IN
RDY
Ready/Busy
Communication Control
with Main Micro Controller
42
IN
FID
Video Presence Detector
Signal
43
-
N.U.
Not Used
44
-
N.U.
Not Used
45
OUT INSEL-0
Audio Input Select Signal
46
OUT INSEL-1
Audio Input Select Signal
47
OUT A-MUTE
Audio Mute Control Signal
48
-
N.U.
Not Used
49
IN
RW-OEX
For Flash Memory Writing
50
OUT
SUB-
SCLK
Communication Clock with
Main Micro Controller
Pin
No.
IN/
OUT
Signal
Name
Name Function
51
OUT SUB-TXD
Transmission Data to Main
Micro Controller
52
IN
SUB-RXD
Reception Data from Main
Micro Controller
53
OUT SUB-SCL
Serial Clock
54
IN/
OUT
SUB-SDA
Serial Data
55
-
N.U.
Not Used
56
-
N.U.
Not Used
57
IN
VCC
+5V Power Supply
58
IN
V-REF
Reference Voltage
59
-
AVSS
Ground
60
-
N.U.
Not Used
61
OUT
REG-
CONT
Power Regulator Control
Signal
62
IN
AFT
Tuner Voltage Input Signal
63
IN
SDET-1
Aspect Ratio Detector
Signal
64
IN
POW-SW
Abnormal Voltage
Detection
Pin
No.
IN/
OUT
Signal
Name
Name Function