Emerson Enardo ES-800 Series Instruction Manual Download Page 6

!

WARNING

4.  Inspect the pressure seal. Remove any debris on 

this seal. If there are any tears or cracks in the 

seal, replace the pressure seal immediately.

V-ring Replacement

Ensure the tank is at atmospheric 

pressure before opening. A pressure 

build-up inside the tank can cause a 

spray to be emitted from the vent valve if 

opened under pressure.

1.  Remove the pallet assembly. Grasp the pressure 

seal firmly by the lip and pull out.

2. 

Insert the new seal. Use a finger, wrench or other 

smooth edge to apply a firm pressure while sliding 

around the entire seal several times. When the 

seal is completely seated, there will be no humps 

or waves in the lip.

Parts Ordering 

When corresponding with your local Sales Office about 

this equipment, always reference the equipment serial 

number that can be found etched on the body.
When ordering replacement parts, specify the 

complete 7-character part number of each required 

part as found in the following parts list.

Parts List

ES-800 Series In-line Vent Valve

Key  Description  

Part Number

Valve Body

2 in. / 50 mm 

3514261

3 in. / 80 mm 

3514297

4 in. / 100 mm 

3514321

2 Lid

2 in. / 50 mm 

3514264

3 in. / 80 mm 

3514300

4 in. / 100 mm 

3514335

Flange Gasket

2 in. / 50 mm 

3505501

3 in. / 80 mm 

3505502

4 in. / 100 mm 

3505503

Pipe Plug 

2023802

Slip-on Flange

2 in. / 50 mm 

3508901

3 in. / 80 mm 

3508902

4 in. / 100 mm 

3508903

Hex Bolt

2 in. / 50 mm 

2021203

3 in. / 80 mm 

2021200

4 in. / 100 mm 

2021200

Square Nut 

2021901

8 Eyebolt 

3505601

Wing Nut 

2001002

10 

Latch Pin 

4505103

11 

Latch Clip (HPC-148) 

2027100

12 

Pallet Assembly 

See Table 3

13 

V-ring Seal 

See Table 4

14 

Lid O-ring

Buna-N 

2 in. / 50 mm 

3514285

3 in. / 80 mm 

3514318

4 in. / 100 mm 

3514365

Viton

®

2 in. / 50 mm 

3514314

3 in. / 80 mm 

3514319

4 in. / 100 mm 

3514372

15 

Nylock Nut 

1/2-13

16 

Pressure Weight (as required) 

- - - - - - -

Viton

®

 is a mark owned by E. I. du Pont de Nemours and Company.

6

ES-800 and ES-900 Series

North America 

Only

Summary of Contents for Enardo ES-800 Series

Page 1: ...lified person may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the vent valves Introduction Scope of the Manual This Instruction Manual provides instructions for installation maintenance and parts ordering guide for the ES 800 and ES 900 Series vent valves Product Description E...

Page 2: ...he unit s hood Actual layout of nameplate may vary WARNING Installation Wear protective gloves and clothing to prevent skin contact when handling lead weights Wear eye protection Avoid breathing dust fumes mist vapors spray Do not eat drink or smoke while using the product Avoid release to the environment Wash hands with soap and water after handling Keep away from excessive heat and open flames S...

Page 3: ... 100 mm 1 0 to 16 0 oz sq in 4 3 to 6 90 mbar 0 5 oz sq in 2 mbar increments 0 4 oz sq in 1 7 mbar ES 800 PSO N A ES 900 SO 0 4 oz sq in 1 7 mbar ES 900 PSO N A Table 2 Construction Materials MODEL HOUSING SEAT PALLET PALLET SEAL HARDWARE WEIGHTS GASKETS ES 800 SO Cast Aluminum Aluminum Buna N or Viton Zinc plated carbon steel Zinc plated carbon steel to 12 oz sq in or Lead Buna N or Viton ES 800 ...

Page 4: ...m the flange and towards the valve Repeat on the other pipe using the second flange 3 Reinstall the flange bolts and nuts one on each side Tighten bolts until flanges are flushed against the body 4 Install the pallet assembly The center rib of the pallet should be in line with the rib on the body Then close the lid and tighten the wing nuts on both sides Check for proper alignment between the lid ...

Page 5: ...Do not use greases or oils on guide rods These will not allow the vacuum assembly to work properly 1 Remove the pallet assembly from the valve Pull the vacuum disk down until it stops and release it If the vacuum disk does not return to the closed position clean the rods with a mild solvent and apply a graphite lubricant If cleaning does not fix the problem replace the pallet assembly immediately ...

Page 6: ...cement parts specify the complete 7 character part number of each required part as found in the following parts list Parts List ES 800 Series In line Vent Valve Key Description Part Number 1 Valve Body 2 in 50 mm 3514261 3 in 80 mm 3514297 4 in 100 mm 3514321 2 Lid 2 in 50 mm 3514264 3 in 80 mm 3514300 4 in 100 mm 3514335 3 Flange Gasket 2 in 50 mm 3505501 3 in 80 mm 3505502 4 in 100 mm 3505503 4 ...

Page 7: ...Table 4 13 Guide Rod 2 in 50 mm 3514344 3 in 80 mm 3514345 4 in 100 mm 3514346 14 Lever 3514350 15 Lever Spring 3514351 16 Screen 2 in 50 mm 3514330 3 in 80 mm 3514347 4 in 100 mm 3514348 17 Pressure Weight as required Viton is a mark owned by E I du Pont de Nemours and Company ES 800 SERIES ES 900 SERIES NOTE TOP LID AREA IS ROTATED 90 DEGREES Figure 7 ES 800 and ES 900 Series Assembly Drawing Ta...

Page 8: ...hout notice Emerson Process Management Regulator Technologies Inc does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Figure 8 ES 900 Series Assembly Drawing NOTE PARTS A AND B ABOVE ARE USED IN BOTH ES 800 AND...