Emerson Enardo ES-800 Series Instruction Manual Download Page 1

!

ES-800 and ES-900 Series Vent Valves

Instruction Manual

D103855X012
April 2020

Table of Contents

Introduction ..................................................................1
Specifications ..............................................................2
Principle of Operation ..................................................2
Model Identification......................................................2
Installation ...................................................................2
Maintenance ................................................................5
Parts Ordering .............................................................6
Parts List......................................................................6

WARNING

Failure to follow these instructions or 

to properly install and maintain this 

equipment could result in an explosion, 

fire and/or chemical contamination 

causing property damage and personal 

injury or death.
Enardo™ vent valves must be installed, 

operated and maintained in accordance 

with federal, state and local codes, rules 

and regulations, and Emerson Process 

Management Regulator Technologies 

Tulsa, LLC instructions.
Failure to correct trouble could result in 

a hazardous condition. Call a qualified 

service person to service the unit. 

Installation, operation and maintenance 

procedures performed by unqualified 

person may result in improper adjustment 

and unsafe operation. Either condition may 

result in equipment damage or personal 

injury. Only a qualified person shall install 

or service the vent valves.

Introduction

Scope of the Manual

This Instruction Manual provides instructions for 

installation, maintenance and parts ordering guide for 

the ES-800 and ES-900 Series vent valves.

Product Description

ES-800 and ES-900 Series vent valves represent the 

latest development in high-performance, tight-sealing tank 

venting products, and complement Enardo’s industry-

leading ES-600 Series thief hatch product line. With a 

leakage rate of no more than 1 SCFH at 90% of set point, 

the ES-800 and ES-900 Series offers unparalleled vent 

valve performance.

Model ES-800-SO –

 is an In-line vent valve. It is 

installed directly into the vent line exhaust. The  

Model ES-800-SO has both pressure and vacuum 

relief capability.

Figure 2.

 Typical ES-900 Series End-of-Line Vent Valve

Figure 1. 

Typical ES-800 Series In-Line Vent Valve

ES-800 and ES-900 Series

North America 

Only

Summary of Contents for Enardo ES-800 Series

Page 1: ...lified person may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the vent valves Introduction Scope of the Manual This Instruction Manual provides instructions for installation maintenance and parts ordering guide for the ES 800 and ES 900 Series vent valves Product Description E...

Page 2: ...he unit s hood Actual layout of nameplate may vary WARNING Installation Wear protective gloves and clothing to prevent skin contact when handling lead weights Wear eye protection Avoid breathing dust fumes mist vapors spray Do not eat drink or smoke while using the product Avoid release to the environment Wash hands with soap and water after handling Keep away from excessive heat and open flames S...

Page 3: ... 100 mm 1 0 to 16 0 oz sq in 4 3 to 6 90 mbar 0 5 oz sq in 2 mbar increments 0 4 oz sq in 1 7 mbar ES 800 PSO N A ES 900 SO 0 4 oz sq in 1 7 mbar ES 900 PSO N A Table 2 Construction Materials MODEL HOUSING SEAT PALLET PALLET SEAL HARDWARE WEIGHTS GASKETS ES 800 SO Cast Aluminum Aluminum Buna N or Viton Zinc plated carbon steel Zinc plated carbon steel to 12 oz sq in or Lead Buna N or Viton ES 800 ...

Page 4: ...m the flange and towards the valve Repeat on the other pipe using the second flange 3 Reinstall the flange bolts and nuts one on each side Tighten bolts until flanges are flushed against the body 4 Install the pallet assembly The center rib of the pallet should be in line with the rib on the body Then close the lid and tighten the wing nuts on both sides Check for proper alignment between the lid ...

Page 5: ...Do not use greases or oils on guide rods These will not allow the vacuum assembly to work properly 1 Remove the pallet assembly from the valve Pull the vacuum disk down until it stops and release it If the vacuum disk does not return to the closed position clean the rods with a mild solvent and apply a graphite lubricant If cleaning does not fix the problem replace the pallet assembly immediately ...

Page 6: ...cement parts specify the complete 7 character part number of each required part as found in the following parts list Parts List ES 800 Series In line Vent Valve Key Description Part Number 1 Valve Body 2 in 50 mm 3514261 3 in 80 mm 3514297 4 in 100 mm 3514321 2 Lid 2 in 50 mm 3514264 3 in 80 mm 3514300 4 in 100 mm 3514335 3 Flange Gasket 2 in 50 mm 3505501 3 in 80 mm 3505502 4 in 100 mm 3505503 4 ...

Page 7: ...Table 4 13 Guide Rod 2 in 50 mm 3514344 3 in 80 mm 3514345 4 in 100 mm 3514346 14 Lever 3514350 15 Lever Spring 3514351 16 Screen 2 in 50 mm 3514330 3 in 80 mm 3514347 4 in 100 mm 3514348 17 Pressure Weight as required Viton is a mark owned by E I du Pont de Nemours and Company ES 800 SERIES ES 900 SERIES NOTE TOP LID AREA IS ROTATED 90 DEGREES Figure 7 ES 800 and ES 900 Series Assembly Drawing Ta...

Page 8: ...hout notice Emerson Process Management Regulator Technologies Inc does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Figure 8 ES 900 Series Assembly Drawing NOTE PARTS A AND B ABOVE ARE USED IN BOTH ES 800 AND...

Reviews: