background image

Seat Ring Maintenance

Note

These joints should be made up with 

high temperature gasket compound. 

1.  Remove old compound from body and seat ring 

with a wire brush. 

2.  Apply new compound sparingly to both parts, 

threads and shoulders. Let stand until tacky 

before assembling.

Parts Ordering

When corresponding with your local Sales Office about 

Type E5 Main Valve, always reference the assembly 

number. When ordering replacement parts, specify 

the complete character part number from the following 

parts list.

Parts List

Key   Description 

 Part Number

 

Type E5 

NPS 3/4 to 3 / DN 20 to 80 

See Table 4

NPS 4 to 12 / DN 100 to 300 

See Table 5

Maintenance

 

 WARNING

To avoid personal injury or property 

damage from sudden release of pressure, 

isolate the regulator from the pressure 

system and release all pressure from the 

pilot and main valve before performing 

maintenance operations.

Inspection

Under normal conditions, complete dismantling is not 

recommended. 
Check the following after operation. Then, schedule an 

inspection as required.

1.  Inspect for dirt collected at 4A bleed port.
2.  Inspect all joints for leakage. Keep bolts tight to 

avoid any leaks

Main Valve Maintenance (See Figure 5)

1.  Connect a source of air or water pressure which 

can be adjusted by hand to the No. 5B elbow. 

2.  Apply 30 psi / 2.07 bar to jack valve open and 

prevent stem from turning while removing 

stem nuts. 

3.  Use penetrating oil on the threads.

Grinding In

 

 CAUTION

Seats and discs should never require 

more than the lightest touch up with very 

fine (400 grit) grinding compound. Heavy 

grinding will produce galling, wider 

seating surface and a groove in the disc, 

all of which tend to cause leakage. 

3.  Reface a damaged surface before attempting to 

grind it in.

4.  Grind sparingly. 
5. 

Main stem (key 13, Figure 4) is slotted for rotation 

with a screwdriver, valve spring (key 14) is omitted 

from the assembly during grinding. 

6.  Slip the stem into its normal position. 
7.  Apply compound to the disc. Place it on the stem 

and guide plug, tighten with stem nut.

8.  After grinding, disassemble and clean all parts.

7

Type E5

Summary of Contents for E5

Page 1: ...e operation Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the Type E5 main valve Introduction Scope of the Manual This manual provides instructions for the installation troubleshooting maintenance valve setting and parts ordering for Type E5 main valve regulator Product Description The Spence Type E5 Main Valve is pilot operated...

Page 2: ...in Valve Pressure and Temperature Rating SEAT FACTOR REGULATOR SIZE NPS DN 3 4 20 1 25 1 1 4 32 1 1 2 40 2 50 2 1 2 65 3 80 4 100 5 125 6 150 8 200 10 250 12 300 Full 7 6 11 7 18 9 27 4 43 67 95 159 258 350 665 1018 1611 Normal 5 7 10 0 13 4 19 8 25 35 59 120 176 228 366 525 952 VALVE SIZE CAST IRON CAST STEEL NPT CL125 CL250 CL150 CL300 NPS DN lbs kg lbs kg lbs kg lbs kg lbs kg 3 4 20 23 10 1 25 ...

Page 3: ...ts given in the Specifications section and or regulator nameplate Additionally physical damage to the regulator may result in personal injury or property damage due to escaping of accumulated gas To avoid such injury and damage install the regulator in a safe location Under enclosed conditions or indoors escaping gas may accumulate and be an explosion hazard In this case the vent should be piped o...

Page 4: ...let of the main valve body Note bleed orifice in this fitting is vital to operation of regulator 3 Screw 8B tee into 1 8 in pipe tap in pilot Select tap facing downstream 4 Screw No 5B elbow into 1 8 pipe tap on underside of main valve diaphragm chamber 5 Connect tubing bends as illustrated in Figure 3 AT LEAST 20 PIPE DIAMETERS D2 TO FIRST TURN SECONDARY PRV OR CONTROL VALVE RECOMMENDED AT LEAST ...

Page 5: ...se 1 4 in pipe for this line which connect the pilot diaphragm chamber to the desired point of pressure control 2 Take the control at a point of minimum turbulence Avoid control immediately at the valve outlet or after a turn 3 When the delivery pipe expands in size select a spot at least 4 pipe diameters beyond the point of enlargement 4 Pitch away from pilot to avoid erratic operation and excess...

Page 6: ...g Failure to Open If the main valve failed to open check the following possible causes to properly correct the problem Adjusting spring on pilot may have been tampered with Initial pressure may be down due to partially closed supply valve clogged strainer or other obstruction No 4A bleed port fitting may have been omitted and an open coupling substituted Control pipe may be plugged Most likely poi...

Page 7: ...ot recommended Check the following after operation Then schedule an inspection as required 1 Inspect for dirt collected at 4A bleed port 2 Inspect all joints for leakage Keep bolts tight to avoid any leaks Main Valve Maintenance See Figure 5 1 Connect a source of air or water pressure which can be adjusted by hand to the No 5B elbow 2 Apply 30 psi 2 07 bar to jack valve open and prevent stem from ...

Page 8: ...00 WAL04 00518 00 WAL04 00518 00 WAL04 00518 00 WAL04 00521 00 WAL04 00521 00 WAL04 00548 00 WAL04 00548 00 WAL04 00520 00 WAL04 00520 00 12 Stem 125 lb Stem 250 lb Steam Internal balance Stainless Steel Stainless Steel Stainless Steel WAL04 05232 01 WAL04 05643 00 WAL04 05242 01 WAL04 05242 01 WAL04 11180 00 WAL04 05246 01 WAL04 05246 01 WAL04 05645 00 WAL04 05383 01 WAL04 05383 01 WAL04 03132 00...

Page 9: ... 00522 01 WAL04 00515 00 WAL04 00522 01 WAL04 00519 01 WAL04 00523 00 WAL04 00519 01 WAL04 00523 00 WAL04 00516 01 WAL04 00517 01 WAL04 00524 02 WAL04 00524 02 12 Stem 125 lb Stem 250 lb Steam Internal balance Stainless Steel Stainless Steel Stainless Steel WAL04 05281 00 WAL04 05384 01 WAL04 08233 00 WAL04 05287 01 WAL04 05386 01 WAL04 05831 00 WAL04 05374 00 WAL04 05385 01 WAL04 10709 00 WAL04 0...

Page 10: ...Figure 4 Type E5 Assembly Drawing NO 5A RESTRICTION ELBOW SERIAL NUMBER PLATE INNER VALVE ASSEMBLY SIZES 3 8 IN 1 1 2 IN PORT INCLUSIVE INTERNAL BALANCED INTEGRAL MOUNTED BLIND FLANGE 10 Type E5 ...

Page 11: ...2 40 7 16 5 32 x 13 16 5 32 2 50 9 16 5 32 x 15 16 5 32 2 1 2 65 1 1 16 3 16 x 15 16 3 16 3 80 1 3 16 3 16 X 1 3 8 3 16 4 100 1 1 16 1 4 X 1 3 4 1 4 5 125 1 5 16 5 16 X 1 3 4 5 16 6 150 1 9 16 5 16 X 2 5 16 8 200 2 1 16 3 8 X 2 3 8 10 250 2 9 16 3 8 X 2 1 2 3 8 12 300 3 1 16 1 2 X 2 3 4 1 2 Table 6 Type E5 Main Valve K Values K TOTAL TRAVEL SETTING STEM SPRING BASE STOP PRESSURE PLATE DOWEL GROOVE...

Page 12: ...are property of their prospective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are...