E300 Installation and Commissioning Guide
91
Issue Number: 1
5.4 Security and parameter access
The navigation buttons can only be used to move between menus and parameters if the parameter access level
User Security Status
(
H02
) has been
set to show 'All Menus'. The security and parameter access level determines whether the user has access to User Menu A only, or to all menus in
addition to User Menu A. The security also determines whether the user has read only (RO) or read write (RW) access. The
E300 Advanced Elevator
drive provides a number of different levels of security that can be set by the user via
User Security Status
(
H02
) as shown in Table 5-6.
Table 5-6 Security and parameter access
The default security and parameter access levels for the drive are,
•
Parameter access level = User Menu A
•
Security = Open i.e. read / write access to User Menu A with the all menus not visible.
Both the security and parameter access level can operate independently of each other as shown in Table 5-7
Security, Parameter access level
Table 5-7 Security, Parameter access level
5.5 Changing security and parameter access
The security level is determined by the setting of
User Security Status
(
H02
). The security level can be changed through the keypad even if a security
code has been set. The security code, when set, prevents write access to any of the parameters in any menu.
5.5.1 Setting security code
Enter a security code value between 1 and 2147483647 in
User Security Code
(
H01
) and press the
button; the security code has now been
set to this value.
5.5.2 Setting parameter access level
To activate the security, the parameter access level must be set to the desired level in
User Security Status
(
H02
). When the drive is reset, the
security code will have been activated and the drive returns to User Menu A and the
symbol is displayed in the right hand corner of the keypad
display. The value of
User Security Code
(
H01
) will return to 0 in order to hide the security code.
5.5.3 Unlocking security code
Select a parameter that needs to be edited and press the
button, the upper display will now show ‘Security Code’. Use the arrow buttons to
set the security code and press the
button. With the correct security code entered, the keypad display will revert to the parameter selected in
edit mode. If an incorrect security code is entered, the following message ‘Incorrect security code’ is displayed, then the display will revert to
parameter view mode.
5.5.4 Disabling security
To unlock the previously set security code as detailed above. Set
User Security Code
(
H01
) to 0 and press the
button. The security has now
been disabled, and will not have to be unlocked each time the drive is powered up to allow read / write access to the parameters.
User Security Status
(H02)
Description
User Menu A (0)
All writable parameters are available to be edited but only parameters in User Menu A are visible
All menus (1)
All parameters are visible and all writable parameters are available to be edited
Read- only User Menu A (2)
Access is limited to User Menu A parameters only. All parameters are read-only
Read-only (3)
All parameters are read-only however all menus and parameters are visible
Status only (4)
The keypad remains in status mode and no parameters can be viewed or edited
No access (5)
The keypad remains in status mode and no parameters can be viewed or edited
Security status
Parameter access level
Security
User Menu A status
All Menus status
0
User Menu A
Open
RW
Not visible
Closed
RO
Not visible
1
All Menus
Open RW
RW
Closed
RO
RO
2
Read-only User Menu A
Open
RO
Not visible
Closed
RO
Not visible
3
Read-only
Open
RO
RO
Closed
RO
RO
4
Status only
Open
Not visible
Not visible
Closed
Not visible
Not visible
5
No access
Open
Not visible
Not visible
Closed
Not visible
Not visible
Disabling security can lead to parameter values being changed without careful consideration; ensure a security code is active to avoid
incorrect or unintentional parameter adjustments which could lead to damage or a safety hazard.
WARNING