background image

READ AND SAVE THESE INSTRUCTIONS

Part No. F40BP73610000

Form No. BP7361

U.L. Model No.: CF3100

Net Weight:  

26.0

Lbs.

Model Numbers

DUNNINGTON

Ceiling Fan

Owner's Manual

CF3100AGW00

Aged Walnut

CF3100BZH00

Bronze Heritage

Summary of Contents for DUNNINGTON CF3100AGW00

Page 1: ...ND SAVE THESE INSTRUCTIONS Part No F40BP73610000 Form No BP7361 U L Model No CF3100 Net Weight 26 0 Lbs Model Numbers DUNNINGTON Ceiling Fan Owner s Manual CF3100AGW00 Aged Walnut CF3100BZH00 Bronze Heritage ...

Page 2: ... contact with th fan blades 5 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician CAUTION The halogen bulb operates at high internal pressure and high surface temperatures and could shatter unexpectedly The halogen bulb generates UV ultraviolet radiation that may cau...

Page 3: ... or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING WARNING 1 Open styrofoam unit containing fan Remove upper and center sections of styrofoam unit Remove parts and check to see that you have received the following a One Fan Motor and Housing Assembly b One Ceiling Cover c Five Fan Blades d Five Flange Assemblie...

Page 4: ...fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electric...

Page 5: ...IRE CONNECTOR LIGHT KIT ASSEMBLY SWITCH HOUSING 4 PIN CONNECTORS Figure 3 8 32 x 10mm PAN HEAD SCREWS 3 LIGHT KIT ASSEMBLY KEYHOLE SLOT 2 Figure 4 12 Carefully turn over the partially assembled ceiling fan and place onto the flat surface of the styrofoam 13 Obtain the hanger ball downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely do...

Page 6: ...RE MOTOR HOUSING WHITE WIRE DECORATIVE UPLIGHT KIT ONE PIN CONNECTOR DECORATIVE UPLIGHT KIT WHITE WIRE DECORATIVE UPLIGHT KIT BLACK WIRE Figure 7 DECORATIVE UPLIGHT KIT 8 32 x 10mm PAN HEAD SCREW 4 15 WATT min CANDELABRA LIGHT BULBS 3 Figure 8 23 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 10 24 Reinstall the hanger b...

Page 7: ...ANGER BRACKET TAB OUTLET BOX Figure 12 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 2 Carefully lift the fan ...

Page 8: ...lectrical supply circuit before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 14 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 14 3 Using w...

Page 9: ...ide of the hanger bracket and into the outlet box Push the green equipment earth ground and white grounded neutral wires into one side of the outlet box push the black blue and yellow ungrounded wires into the other side of the outlet box Figure 15 6 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 16 7 Lift the ceiling cover up to the threaded studs a...

Page 10: ...off before attempting to install or replace the 50 watt max bi pin halogen bulb CAUTION To not touch 50 watt max bi pin halogen bulb with bare hands Fingerprints may result in shorter bulb life Remove fingerprints with alcohol Light Kit Installation NOTE Do not install the 50 watt max bi pin halogen bulb or unhook the 50 watt max bi pin halogen bulb from light kit socket 1 Place the non light swit...

Page 11: ...f Wall Control and Receiver Figure 21 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small sc...

Page 12: ...its for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to radio communications However there is not gu...

Page 13: ...smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories 1...

Page 14: ...14 1 8 9 10 3 2 7 5 17 31 18 19 4 6 21 11 24 23 12 22 26 27 28 15 16 30 25 14 29 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 32 20 13 13 Repair Parts U L Model No CF3100 U L Model No CF3100 ...

Page 15: ...63502 AGW 763502 BZH 21 K55XL Motor 1 762508 762508 22 Flange Assembly 5 per set 763506 AGW 763506 BZH 23 Flange Medallion Assembly 5 per set 763508 AGW 763508 BZH 24 Blade Assembly 5 per set 763512 1 763512 25 Lower Light Kit Assembly 1 763514 AGW 763514 BZH 26 Halogen 50 Watt Bi Pin Type GY8 1 27 Glass Shade 1 763516 763516 28 Non Light Switch Cover 1 763517 AGW 763517 BZH 29 Reverse Module 7634...

Page 16: ... an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The ...