11.
Remove the housing from the flameproof pad.
12.
Uninstall the O-ring from the pad.
9.6
Electronics enclosure assembly
WARNING!
ELECTRONIC HAZARD
Power off the electronics after every use.
Servicing the turbine meter while powered may result in death or serious injury.
Important
Do not use a hammer to assemble the housing.
NOTICE
The joint between the LME cover and housing is a threaded joint. The joint between the LME
housing and Sensor housing is a spigot joint with a minimum axial length of 26.16 mm (1.030
in), radial length of 3.18 mm (0.125 in), and a clearance of 0.07 mm (0.0028 in).
9.6.1
Assemble the LME/RME - Standard enclosure
1.
Install the O-ring on the pad.
2.
Install the housing on the turbine meter body or remote mounting pad. Use four
screws with a torque value of 74.5 Nm (55 lbs-ft) (Capacity to be installed: each at
90º).
3.
For LME only - Insert pickoffs and anti-rotation bracket.
4.
Install the conduit.
5.
Install the internal and external grounding cable to lug.
6.
Tighten the preamplifier socket screw to the bracket plate.
7.
Follow the applicable diagram for the wiring configuration. The preamplifier
connectors can be removed by pulling each connector. Refer to
preamplifier designator. Ensure the torque is less than 4 lbs·in.
8.
Tighten the socket screws from the plate bracket to the housing.
9.
Install the solid end cap.
10.
Install the security seals.
11.
Install the security seal wire.
9.6.2
Assemble the LME - High temperature enclosure
1.
Install the O-ring to the pad.
Planned maintenance
82
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...