Universal replacement cores and filter cores for use in our ADKS and
STAS shells and similar competitive Take-Apart type Filter Drier shells.
May not be used for BTAS.
Features
•
Water capacities to suit specific system conditions
•
Exceptional acid capacities for normal system protection,
or to effectively clean-up following a compressor burnout
•
Activated carbon blend for soluble contaminant and wax removal
(W-HH Series)
Nomenclature:
H
48
Series
(in
3
)
Ordering Information:
PCN
Type
Refrigerant
Function
Water Capacity
1
(g)
R 134a
R 22
R 407C
R 404A
/R 507
R 410A
24oC 52oC 24oC 52oC 24oC 52oC 24oC 52oC 24oC 52oC
059541
D-48
HCFC
High Acid Removal
20.8 17.0 18.2 12.7 11.3 4.8 22.9 17.2 10.5 4.3
059542
H-48
HCFC
High Acid and Water
Removal
33.8 26.9 29.9 21.8 22.3 14.3 36.1 26.8 19.0 11.3
061235 W-48-HH HCFC, HFC
Burnout Cleanup
19.4 14.7 16.8 11.3 14.5 8.3 20.9 14.5 12.5 6.5
061617
UK-48
CFC, HCFC,
HFC
Universal Replacement
1272 1168 1181 1072 1033 786 1319 1241 976 707
089338
H-100
HCFC
High Acid and Water
Removal
55.6 41.7 48.1 33.7 36.3 20.9 60.0 42.0 33.6 18.2
043582 W-100-HH HCFC, HFC
Burnout Cleanup
53.9 40.6 46.9 31.1 31.5 18.2 58.1 39.6 28.7 15.4
089559
F-48
HCFC, HFC
Filter (Suction Only)
-
095762
F-100
HCFC, HFC
Filter (Suction Only)
-
Note: 1. Water Capacities are based on Equilibrium Point Dryness (EPD) of:
50 parts per million for R 134a, R 404A/R 410A and R 407C, 60 parts per million for R 22
Filter drier
block size
Dimensions (mm)
Weight (kg)
A
B
C
42
152.4
40.1
79.2
0.5
48
139.7
45.0
94.5
0.7
100
165.1
52.3
122.2
2.0
Filter drier
block size
Dimensions (mm)
Weight (kg)
A
B
C
F48/F48R
140.0
71.4
98.6
0.3
F100
165.0
95.3
122.2
0.7
Cores And Filters
Filter-Drier Cores And Filters
Dimensional Data (mm):
Capacity Table (in Tons)
Liquid Line for Replaceable Block Type ADKS Filter Driers
Type
Connection
Size (inch)
Flow Capacity at 0.07 bar pressure drop 1,2
(kW)
R-12
R 134a
R 22/R 410A
R 407C
R 404/507
R-502
ADKS 30013T
1 5/8 ODF
83
102
110
108
73
49
ADKS 30017T
2 1/8ODF
121
148
160
157
107
59
ADKS 40017T
2 1/8ODF
128
157
170
167
114
63
ADKS 40021T
2 5/8ODF
136
166
180
177
120
71
Notes:
1
All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature
5
o
F saturated vapor temperature
3.1 lbs./min./ton for R-134a
2.9 lbs./min./ton for R-22 and R-407C
4.0 lbs./min./ton for R-404A/507 and R-12
2
For 2 PSI ΔP. Multipy values by 1.4
Summary of Contents for Copeland Scroll
Page 1: ...CopelandScroll TM ZBdigitalcompressor ...
Page 17: ...14 Dimensional Drawings ZBD29KQ E BOM558 ...
Page 18: ...15 Dimensional Drawings ZBD38 45KQ E BOM558 ...