COM Express Carrier Type 2
Design
Guide
8.2
Reference Schematic
Figure 15 LVDS Reference Schematic
8.3
Layout Considerations
Route LVDS signals as differential pairs (excluding the five single-ended support signals), with
100 ohms differential impedance and a 55 ohm single-ended impedance. Ideally, an LVDS pair is
routed on a single layer adjacent to a ground plane. LVDS pairs should not cross plane splits. Keep layer
transitions to a minimum. Reference LVDS pairs to a power plane if necessary. The power plane should
be well bypassed. Length-matching between the two lines that make up an LVDS pair (intra-pair) and
between different LVDS pairs (inter-pair) is required. Intra-pair matching is tighter than the inter-pair
matching. All LVDS pairs should have the same environment, including the same reference plane and
the same number of vias. LVDS routing rules are summarized in Section 21.3.7 LVDS Trace Routing
Guidelines.