background image

Part No. F40BP73360000

Form No. BP7336

Printed in China  11/06

Air Comfort Products

DIVISION OF Emerson Electric Co.

8100 W. Florissant ¥ St. Louis, MO 63136

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in
workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. All other com-
ponents and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COM-
PONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at
no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement
can be provided, Emerson will refund the actual purchase price of your fan. We will ship the repaired product or replacement
to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson
Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP
YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized
service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort

Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers
shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized ser-

vice center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center.
Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible
for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any
defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and

tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral
warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson
Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL
DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential
damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product
does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.

Summary of Contents for CF654AW00

Page 1: ...BP73360000 Form No BP7336 U L Model No CF653 READ AND SAVE THESE INSTRUCTIONS Model No CF654AW00 CF654OB00 CF654ORB00 CF654WB00 CF654WW00 WET LOCATION Net Weight 18 7 Lbs 52 Ceiling Fan Owner s Manual ENERGY STAR ...

Page 2: ... Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot...

Page 3: ...ll steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 ...

Page 4: ...ening faces upward Figure 3 5 Reinstall the hanger ball on the downrod as follows Figure 4 Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose ...

Page 5: ...hanging and the electrical wiring of your fan Electrical Requirements 5 BLADE FLANGE FAN BLADE M5 x 6 WASHER HEAD BLADE SCREW 3 RIB LINE THIS SIDE UP Figure 5 SWITCH HOUSING MOTOR HUB M6 x 14 FLANGE SCREWS WITH LOCKWASHERS 2 Figure 6 To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign ob...

Page 6: ...sk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box and joist must be securely mounted and capable of supporting at least 50 ...

Page 7: ...re and blue wire to the supply black hot wire using a wire connector supplied Figure 10 Your fan is now wired to be turned on and off from the fan switch After connections have been made turn leads upward and carefully push leads into the out let box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all c...

Page 8: ...rol device WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the ...

Page 9: ...ade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balance 6 In...

Page 10: ...ave been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 Repair Parts 10 ...

Page 11: ...Housing Cover 763117 WW 763117 OB 763117 WB 763117 AW 763117 ORB 6 Capacitor 763123 763123 763123 763123 763123 7 Speed Control Switch 763122 763122 1 763122 1 763122 763122 1 8 Reversing Switch 760360 760360 1 760360 1 760360 760360 1 9 Loose Parts Bag 763118 1 763118 763118 763118 2 763118 Containing Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Screw M5 x 6 Washer Head Blade 16 Screw M6 x 14 Flan...

Page 12: ...rized service center call 1 800 654 3545 for the address of the nearest authorized ser vice center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Reviews: