5. Secure the ceiling cover in place by sliding lockwash-
ers over the threaded studs and installing the two
knurled knobs (supplied). (Figure 8). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.
6.Cut the 3-speed switch pull chain to a desired length
(optional). Connect the wood pendant (supplied) to
the 3-speed switch pull chain by sliding the wooden
pendant (small hole first) onto the pull chain. Attach
the chain coupler to the end of the chain and allow the
wooden pendant to fall down over the coupling.
6
CEILING COVER
THREADED STUD
KNURLED KNOB
LOCKWASHERS (2)
Figure 8
NOTE: If you are using an Emerson light fixture
with your fan, remove the three screws securing
the switch housing cover to the switch housing
and remove the cover. Remove the screw plug
from the bottom of the switch housing cover and
install the light in accordance with the light kit
Owner's Manual.
2.Connect the fan motor white wire to the supply
white (neutral) wire using a wire connector (sup-
plied) (Figure 7). Connect the fan motor black wire
and blue wire to the supply black (hot) wire using a
wire connector (supplied) (Figure 7). Your fan is
now wired to be turned on and off from the fan
switch. After connections have been made, turn
leads upward and carefully push leads into the out-
let box, with the white and green leads on one side
of the outlet box and the black and blue leads on
the other side of the outlet box.
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 8).
1.Restore electrical power to the outlet box by turning
the electricity on at the main fuse box.
2.Your fan model is equipped with a 4-position, 3-
speed pull chain switch. Check the operation of the
fan by gently pulling on the pull chain switch. The
operating sequence is as follows:
3.All fans are shipped from the factory with the
reversing switch positioned to circulate air down-
ward. If airflow is desired in opposite direction, turn
your fan off and wait for the blades to stop turning,
then slide the reversing switch to opposite position,
and turn fan on again. The fan blades will turn the
opposite direction and reverse the airflow.
Using Your Ceiling Fan
SPEED
CONTROL
SWITCH
REVERSING
SWITCH
THREE-SPEED
1st Pull — High
2nd Pull — Medium
3rd Pull — Low
4th Pull — Off
NOTE: The reversing switch is covered by a soft
vinyl rubber seal to prevent entry of water into the
switch cup assembly.
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
!
To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.
WARNING
!