background image

5. Secure the ceiling cover in place by sliding lockwash-

ers over the threaded studs and installing the two
knurled knobs (supplied). (Figure 8). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.

6.Cut the 3-speed switch pull chain to a desired length

(optional). Connect the wood pendant (supplied) to
the 3-speed switch pull chain by sliding the wooden
pendant (small hole first) onto the pull chain. Attach
the chain coupler to the end of the chain and allow the
wooden pendant to fall down over the coupling.

6

CEILING COVER

THREADED STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 8

NOTE: If you are using an Emerson light fixture
with your fan, remove the three screws securing
the switch housing cover to the switch housing
and remove the cover. Remove the screw plug
from the bottom of the switch housing cover and
install the light in accordance with the light kit
Owner's Manual.

2.Connect the fan motor white wire to the supply

white (neutral) wire using a wire connector (sup-
plied) (Figure 7). Connect the fan motor black wire
and blue wire to the supply black (hot) wire using a
wire connector (supplied) (Figure 7). Your fan is
now wired to be turned on and off from the fan
switch. After connections have been made, turn
leads upward and carefully push leads into the out-
let box, with the white and green leads on one side
of the outlet box and the black and blue leads on
the other side of the outlet box.

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket.

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 8).

1.Restore electrical power to the outlet box by turning

the electricity on at the main fuse box.

2.Your fan model is equipped with a 4-position, 3-

speed pull chain switch. Check the operation of the
fan by gently pulling on the pull chain switch. The
operating sequence is as follows:

3.All fans are shipped from the factory with the

reversing switch positioned to circulate air down-
ward. If airflow is desired in opposite direction, turn
your fan off and wait for the blades to stop turning,
then slide the reversing switch to opposite position,
and turn fan on again. The fan blades will turn the
opposite direction and reverse the airflow.

Using Your Ceiling Fan

SPEED
CONTROL
SWITCH

REVERSING
SWITCH

THREE-SPEED
1st Pull — High
2nd Pull — Medium
3rd Pull — Low
4th Pull — Off

NOTE: The reversing switch is covered by a soft
vinyl rubber seal to prevent entry of water into the
switch cup assembly.

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.

WARNING

!

Summary of Contents for CF653WW00

Page 1: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Page 2: ...upporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the out let box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan b...

Page 3: ... downrod assembly f One hanger bracket g One loose parts bag containing 1 Sixteen 3 16 24 x 5 16 screws 2 Eleven 1 4 20 x 7 16 blade flange screws 3 One wood ball 4 Three wire connectors 5 One 3 16 24 x 1 1 2 round head stainless steel screw 6 One acorn nut 7 Two rubber washers 8 Two threaded studs 9 Two lockwashers 10 Two knurled knobs 11 One chain coupling NOTE Place the parts from the loose par...

Page 4: ...ASHER ACORN NUT RUBBER WASHERS 2 SHOULDER DOWNROD RUBBER WASHER Figure 1 BLADE FLANGE FAN BLADE 3 16 24 x 5 16 SLOTTED PHILLIPS WASHER HEAD BLADE SCREW 3 RIB LINE THIS SIDE UP Figure 2 8 You have now completed the assembly of your new ceiling fan You can now proceed with hang ing and the electrical wiring of your fan SWITCH HOUSING MOTOR HUB 1 4 20 x 7 16 BLADE FLANGE SCREWS 2 Figure 3 To reduce t...

Page 5: ... BLACK AND BLUE FAN WIRES Figure 7 NOTE CEILING COVER OMITTED FOR CLARITY 5 The fan must be hung with at least 7 of clearance from floor to blades Figure 4 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accepta...

Page 6: ... and the black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 8 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Your fan model is equipp...

Page 7: ...n blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balance ...

Page 8: ...Blade Hardware Hanging Hardware Pull Chain Ball Pull Chain Coupling Owners Manual BP7237 BP7237 2 1 1 9 9 9 9 9 9 5 9 9 9 8 9 9 3 6 7 9 4 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be fou...