background image

6

U.L. Model No.: CF620

8.

Remove the shipping spacers and the spacer
attachment screws from the motor before
installation of blade assemblies. Discard the
spacers and spacer screws (Figure 6).

9.

Mount blade flanges (supplied with fan) to fan
blades (sold separately) using four #10 - 24 x
12mm washer head screws and four 16mm flat
washers (supplied with fan) (Figure 7).

NOTE: Some accessory blades available are
supplied with shorter screws. These shorter
screws MUST be used to assemble the blades to
flanges.

NOTE: Take care not to scratch fan housing when
installing blades.

10.

Loosely attach one blade/flange assembly to the
motor hub by securing the two 1/4 - 20 x 14mm
captive pan head screws. Make sure the screws
are NOT tightened (Figure 8). Repeat this
procedure for other four blade assemblies.

11.

Once all five blade/flange assemblies are
secured to the motor hub, proceed to tighten all
the 1/4 - 20 x 14mm captive pan head screws at
this time.

12.

Remove one #8 - 32 x 8mm pan head screw
from the lower housing adapter plate (reserve for
later use). Loosen the other two screws to
assemble the lower housing to the lower housing
adapter plate (Figure 9).

13.

Position the lower housing onto the fan motor
assembly, aligning each of the the three holes.
Rotate the lower housing to engage the two
loosened screws in the two key hole slots.
Replace the #8 - 32 x 8mm pan head screw
(removed previously) and tighten all three screws
to secure the lower housing to the lower housing
adapter plate (Figure 9).

NOTE: Make sure wires are not pinched between
lower housing adapter plate and lower housing.

How to Put Your Ceiling Fan Together

(continued)

SPACER ATTACHMENT 
SCREW

SHIPPING 
SPACER

Figure 6

BLADE FLANGE

FAN BLADE
(Sold Separately)

#10 - 24 x 12mm WASHER 
HEAD SCREW 
(4 per blade/flange)

16mm FLAT WASHER
(4 per blade/flange)

Figure 7

1/4 - 20 x 14mm CAPTIVE 
PAN HEAD SCREW (2)

BLADE/FLANGE ASSEMBLY (5)

Figure 8

LOWER HOUSING 
ADAPTER PLATE

LOWER HOUSING

REMOVE ONE #8 - 32 x 
8mm PAN HEAD SCREW

LOOSEN TWO #8 - 32 x 
8mm PAN HEAD SCREWS

Figure 9

To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.

WARNING

!

Summary of Contents for CF620AP00

Page 1: ...450000 Form No BP7445 U L Model No CF620 READ AND SAVE THESE INSTRUCTIONS 52 Wet Location Ceiling Fan Owner s Manual CF620AP00 CF620AW00 CF620VNB00 Model Numbers LAGUNA BAY Net Weight 18 8 Lbs Fan Blades Not Included ...

Page 2: ...sult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enoug...

Page 3: ...re with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembly your ceiling fan refer to section on proper method of wiring your fan page 9 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 354...

Page 4: ...rical shock WARNING WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 1 Remove...

Page 5: ...wobble 6 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Turn fan motor assembly upside down in preparation for mounting fan blades Position the top and bottom halves of the styrofoam packaging on end with ...

Page 6: ...plate reserve for later use Loosen the other two screws to assemble the lower housing to the lower housing adapter plate Figure 9 13 Position the lower housing onto the fan motor assembly aligning each of the the three holes Rotate the lower housing to engage the two loosened screws in the two key hole slots Replace the 8 32 x 8mm pan head screw removed previously and tighten all three screws to s...

Page 7: ...move the three 8 32 x 8mm flat head screws from the switch housing assembly reserve for later use for assembly of the switch housing assembly to the lower housing Figure 11 16 Position the switch housing assembly onto the lower housing aligning each of the the three holes Replace the three 8 32 x 8mm flat head screw removed previously and tighten all three screws to secure the switch housing assem...

Page 8: ...RES OMITTED FOR CLARITY OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY 1 1 4 THREADED STUD 2 Figure 14 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securel...

Page 9: ... contact a licensed electrician for advice as it must be grounded for safe operation NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE BLUE FAN WIRE Check to see that all connections are tight including ground and that no bare wire is...

Page 10: ...U L Model No CF620 Accessories This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage The use of any other control not specifically...

Page 11: ...tors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to flywheel 4 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten th...

Page 12: ...6 1 2 3 4 5 8 7 22 BLADES SOLD SEPARATELY 17 18 19 21 20 10 16 15 14 11 12 13 9 12 Repair Parts U L Model No CF620 ...

Page 13: ...d 1 4 20 x 14mm with Lockwasher 1 14 Pendant with Pull Chain and Coupling 1 15 Wire Connector 3 16 Balancing Kit 1 17 Canopy Ceiling 1 764199 AP 764199 AW 764199 VNB 18 Motor Coupling Cover 1 764032 AP 764032 AW 764032 VNB 19 Wiring Harness 1 764204 764204 1 764204 20 Lower Housing 1 764203 AP 764203 AW 764203 VNB 21 Switch Housing 1 764207 AP 764207 AW 764207 VNB 22 Blade Flanges set of 5 764205 ...

Page 14: ...14 U L Model No CF620 Notes ...

Page 15: ...center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also...

Page 16: ...Part No F40BP74450000 Printed in China 11 11 Form No BP7445 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 U L Model No CF620 ...

Reviews: