Emerson CF550BS00 Owner'S Manual Download Page 8

8

4

Position the light kit assembly onto the fan motor
assembly, safely tucking all wires and connectors
inside the light kit assembly.

5.

Engage the two key slots on the light kit assembly
with two loosened screws in motor housing
assembly. Rotate the light kit assembly clockwise
to engage the two screws into both slots and
tighten securely. Install the previously removed
screw into the remaining hole of the light kit
assembly, attaching it to the fan motor assembly
securely (Figure 12).

6. If no light kit is to be used,

screw the light kit

cover plate into the center hole of the light kit
assembly. Rotate the light kit cover plate
clockwise until fully installed (Figure 13).

CAUTION: To avoid risk of burns or other injury,
assure power is off before attempting to install or
replace the 50-watt (max.) mini-candelabra base
halogen lamps. Halogen lamps are very hot and
can cause burns. Allow the lamps to cool
sufficiently before handling.

CAUTION: To not touch 50-watt (max.) mini-
candelabra base halogen lamps with bare hands.
Fingerprints may result in shorter lamp life.
Remove fingerprints with alcohol.

7. If light kit assembly is to be used as a down

light, 

screw in two 50-watt (maximum) mini-

candelabra base halogen lamps (supplied) into the
light kit assembly light sockets (Figure 14).

8.

Place the light kit glass shade into the light kit
assembly, aligning the three flat areas on the top
flange of the glass shade with the three raised
studs in the light kit assembly. Then turn the glass
shade clockwise until it stops and is secure
(Figure 14).

NOTE: Periodically check that the glass bowl is
seated fully clockwise in the light kit assembly.

9.

Installation of your ceiling fan is now complete.
Proceed with installation of the wall control.

Lower Light Kit Assembly

REMOVE & RETAIN 
ONE SCREW FROM 
MOTOR HOUSING

LIGHT KIT WHITE WIRE

LIGHT KIT BLACK WIRE

WIRE CONNECTORS

MOTOR 
HOUSING 
WHITE WIRE

LIGHT KIT ASSEMBLY

LOOSEN TWO SCREWS

MOTOR HOUSING 
ASSEMBLY

MOTOR HOUSING 
BLACK WIRE

Figure 11

REINSTALL SCREW 

LIGHT KIT 
ASSEMBLY

MOTOR 
HOUSING 
ASSEMBLY

Figure 12

LIGHT KIT 
COVER PLATE

LIGHT KIT 
ASSEMBLY

LIGHT KIT 
ASSEMBLY 
CENTER HOLE

Figure 13

LIGHT KIT 
ASSEMBLY

RAISED 
STUDS (3)

LIGHT KIT 
GLASS SHADE

GLASS SHADE 
FLAT AREAS (3)

LIGHT KIT 
SOCKETS (2)

50-WATT BASE 
LAMPS (2)

Figure 14

ETL Model No.: CF550

Please call Emerson technical support at
1-800-654-3545 if you have any questions
about installation and operation of this ceiling fan.

Make sure all wires and connectors are tucked under
the light kit assembly and not pinched between light
kit assembly and fan motor assembly.

WARNING

!

1.

With the fan assembly safely installed on the
mounting bracket, install the lower light kit as
follows. 

2.

Remove one screw (retain for future use) and
loosen the two other screws in the motor housing
for installation of the light kit assembly (Figure 11).

3.

Connect the white wire from the ceiling fan
assembly to the white wire of the light kit assembly
(Figure 11). Connect the black wire from the ceiling
fan assembly to the black wire of the light kit
assembly.

Summary of Contents for CF550BS00

Page 1: ...SE INSTRUCTIONS 54 Ceiling Fan Owner s Manual CF550BS00 CF550ORB00 Model Number LUXE ECO Net Weight 20 9 Lbs DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use ...

Page 2: ...m the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE All setscrews must be checked and re tightened where necessary before installation NOTE This fan is suitable for use with solid state speed contro...

Page 3: ... local retailer or catalog outlet for replacement before proceeding Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this ...

Page 4: ...WNROD HAIRPIN CLIP DOWNROD HAIRPIN CLIP MOTOR COUPLING CLEVIS PIN SETSCREW 2 Figure 2 PIN HANGER BALL SETSCREW DOWNROD Figure 1 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 3 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 5 2 Loosen setscrews in motor ...

Page 5: ...ove top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Position one fan blade on the flange assembly of the motor assembly and secure by installing four 10 24 x 375 flat head screws and four 10 x 50 flat washers supplied Figure 5 8 Install the remaining four fan blades using the same procedure NOTE Take care not to scratch fan housing wh...

Page 6: ...t must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard 2 Carefully lift the fan and seat the hanger ball downrod assembly onto the hanger bracket that was ...

Page 7: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Check to see that all connections are tight including ground and that no bare wire is visible...

Page 8: ... the three raised studs in the light kit assembly Then turn the glass shade clockwise until it stops and is secure Figure 14 NOTE Periodically check that the glass bowl is seated fully clockwise in the light kit assembly 9 Installation of your ceiling fan is now complete Proceed with installation of the wall control Lower Light Kit Assembly REMOVE RETAIN ONE SCREW FROM MOTOR HOUSING LIGHT KIT WHIT...

Page 9: ...e wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescent bulbs WALL CONTROL CODE SWITCHES ON 1 2 3 4 5 I CODE SWITCHES WALL CONTRO...

Page 10: ...stallation is completed Figure 17 FAN LIGHT WALL CONTROL WALL BOX BLACK BLK HOT SWITCH COVER DECORATIVE WALL PLATE SCREWS 2 NEUTRAL WIRES TO 120VAC SOURCE TO LOAD G R OUND Figure 17 3 WAY INSTALLATION One fan controlled by two different wall controls See Figures 18 and 19 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling...

Page 11: ...ires are visible at the wire connectors WARNING STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLACK SW605 FAN LIGHT WALL CONTROL TRAVELER WIRE BLK BLK LOAD BLACK GROUND NEUTRAL RECEIVER LOCATED ON TOP OF THE CEILING FAN EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 18 Figure 19 HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL FAN LIGHT WALL CONTROL...

Page 12: ...OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan lights if installed will blink to indicate the transmitted has been paired with the receiver IMPORTANT Immediately after successful pairing the ceiling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th ...

Page 13: ...n motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Fan blade flanges are loose or not properly 3 Check to be sure the fan blade flanges are seated properly seated into the blade holders firmly and uniformly into the blade holders If blades are ...

Page 14: ...14 ETL Model No CF550 Repair Parts 1 7 3 2 13 14 6 10 11 18 12 15 16 17 19 20 9 8 5 4 ...

Page 15: ...ng Kit 1 13 Cover Ceiling 1 764240 BS 764240 ORB 14 Coupler Cover 1 762463 BS 762463 ORB 15 Light Kit Assembly 1 764250 BS 764250 ORB 16 Light Kit Cover Plate 1 764256 BS 764256 ORB 17 Light Kit Glass Shade 1 764253 OM 764253 OM 18 Blades set of 5 764248 DM 764248 WA 19 Wall Control Transmitter 6 Speed SW605 SW605 20 Control Receiver 764087 1 764087 1 Owner s Manual BP7453 1 BP7453 1 Before discar...

Page 16: ...d have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your rece...

Reviews: