background image

READ AND SAVE THESE INSTRUCTIONS

Model No.

CF2800PW 00
CF2800BS 00
CF2800WB 00

KITTY HAWK

Part No. F40BP72730000

Form No. BP7273

®

Net Weight:  

34.5 

Lbs.

Ceiling Fan

Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Company will refund the actual purchase
price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and
shipping of the product to Emerson Company.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Summary of Contents for CF2800BS

Page 1: ...rized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass glo...

Page 2: ...d as Acceptable for Fan Support of 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The...

Page 3: ...d studs 5 Two 1 1 4 threaded studs 6 Four knurled knobs 7 Four lockwashers 3 8 Three wire connectors 9 Two pull chain pendants 10 Two plastic couplings 11 One hairpin clip 12 One clevis pin 13 Eleven 10 32 x 1 oval head screws 14 Thirty two 10 32 x 8mm Phillips button head screws 15 Forty two 6 32 x 6mm Phillips button head screws 16 One fiber washer 17 Two 8 32 x 3 8 pan head screws NOTE Place th...

Page 4: ...screw using the setscrew wrench supplied NOTE The setscrews must be properly installed as described above or fan wobble could result 6 Screw two 1 threaded studs supplied into the motor Figure 3 Leave approximately 7 8 of the stud extending above the motor Coil the wires and wire connectors around the motor coupling then slide the motor cover over the downrod and rotate the cover until the threade...

Page 5: ...r ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 9 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads IMPORTANT When instal...

Page 6: ...fan with the light fixture omit steps 19 through 23 and proceed to step 24 19 Remove the nut and lockwasher securing the light fixture to the switch housing cover Figure 12 Unscrew the light fixture from the switch housing cover Retain the light fixture in case you want to install it later 20 Screw the 2 1 4 pipe nipple supplied several full turns into the switch housing cover Figure 13 Reinstall ...

Page 7: ...over Turn the switch housing cover clockwise to engage the slots then securely tighten the two screws Figure 16 NOTE Be sure the wires are not pinched between the switch housing and the switch housing cover Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling...

Page 8: ...push the black and blue leads into the other side of the outlet box THREADED STUD 2 HANGER BRACKET WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET LISTED WIRE CONNECTOR 3 SUPPLY GROUND WIRE GREEN WIRE GROUND FROM HANGER BALL BLACK FAN WIRE BLUE FAN WIRE BLACK SUPPLY HOT WHITE FAN WIRE Figure 20 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs U...

Page 9: ... and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch 6 Screw three candelabra base lamps 60 watt each max in the light fixture sockets Pass the light fixture switch chain through the light fixture glass Figure 22 Position the glass on the light fixture so that the three elongated points of the glass are over the three lamps In...

Page 10: ...4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to Step 17 and Figure 11 5 Hanger bracket and or ceiling outlet box is 5 Tighten the hanger bracket screws to the outlet box and or not securely fastened secure outlet box 6 Fan blades out of balance 6 Interchanging an adj...

Page 11: ...9 38 38 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Page 12: ...66 762466 762466 26 Motor 762304 762304 762304 27 Hub Assembly 762487 762487 762487 28 Washer 9 16 29 Lockwasher 9 16 30 Switch Housing Assembly 762113 11 762113 12 762113 13 31 Wiring Harness Assembly 762090 5 762090 5 762090 6 32 Cover Switch Housing 762425 762425 1 762425 2 33 Light Fixture Assembly 762419 762419 762419 1 34 Glass Light Fixture 762420 762420 762420 35 Cover Plate 762424 762424 ...

Reviews: