background image

U.L. Model No.: CF542

Part No. F40BP74030000

Printed in China  10/09

Form No. BP7403

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant • St. Louis, MO 63136

LIMITED WARRANTY

What The Warranty Covers:

This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in
workmanship and materials. You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:

As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND
ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:

Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at
no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can
be provided, Emerson will refund the actual purchase price of your fan. 

WE WILL SHIP THE REPAIRED PRODUCT OR

REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION
AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR
RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service
center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort

Products, Division of Emerson Electric Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers
shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service

center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service
center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be
responsible for any such damage.

What Is Not Covered:

The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any
defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral
warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson
Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES.
Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages
include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work
properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.

Summary of Contents for CARRERA VERANDA CF542AW00

Page 1: ...30000 Form No BP7403 U L Model No CF542 READ AND SAVE THESE INSTRUCTIONS 42 Ceiling Fan Wet Location Owner s Manual CF542AW00 Summer White CF542ORB00 Oil Rubbed Bronze Model Numbers CARRERA VERANDA Net Weight 17 6 Lbs ...

Page 2: ...ost outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with...

Page 3: ...ore assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories desig...

Page 4: ...ixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To avoid fire or shock follow all wiring instructions carefully Any electrical work not described...

Page 5: ...e so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover 7 Turn the bracket switch housing assembly clockwise and tighten both screws Figure 4 Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly M4 x 12mm FLAT HEAD SCREW 3 SWITCH HOUSING ASSEMBLY Figure 6 To avoid possible fire or shock do not...

Page 6: ...hanger ball Figure 10 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Remove ...

Page 7: ...OD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 13 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan coul...

Page 8: ...g wire connector supplied Figure 14 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 14 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue unground...

Page 9: ...ing fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance Accessories Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock This product ...

Page 10: ...d properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet 5 Tighten the hanger bracket screws to the outlet box is not securely fastened box and or secure out...

Page 11: ...ant 16 Balancing Kit 1 17 Canopy Ceiling 1 763921 AW 763921 ORB 18 Wiring Harness 1 763981 5 763981 3 19 Switch Housing 1 763919 AW 763919 ORB 20 Coupling Cover 1 763922 AW 763922 ORB 21 Flange set of 5 763930 AW 763930 ORB 22 Blade set of 5 763932 AW 763932 ORB 23 Switch Housing Adapter Cover Assembly 763915 AW 763915 ORB Owner s Manual BP7403 BP7403 11 14 13 17 20 21 6 5 9 22 23 10 11 15 18 19 1...

Page 12: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Reviews: